# Dallas Google PoP
|
||
|
||
## New Google POP
|
||
|
||
```
|
||
Site DFW 28
|
||
Cage 4000.40
|
||
1950 N Stemmons Freeway
|
||
Suite 4000
|
||
Dallas, TX 75207
|
||
|
||
Racks 4-11 4-12
|
||
RGnet in 4-12
|
||
IETF/Infra in 4-11
|
||
|
||
Shipping Address:
|
||
Google - chris morrow
|
||
c/o: Infomart Suite 4000
|
||
1950 N Stemmons Freeway
|
||
Dallas, TX 75207
|
||
```
|
||
|
||
## Infra Hardware Inventory
|
||
```
|
||
r1 Juniper MX240
|
||
r2 cisco 9001
|
||
sw0 cisco 2960G-48TC-L with fiber to 12406
|
||
sw2 Nexus3064 48x10GE
|
||
sw3 Nexus3064 48x10GE
|
||
o2 Cyclades® ACS Advanced Console Server
|
||
pwr0 & pwr1 AP7941
|
||
?pwr0 Servertech Horizontal Power Strip (8port) Part Number: CW-8H2-C20
|
||
>pwr1 Servertech Horizontal Power Strip (8port) Part Number: CW-8H2-C20
|
||
```
|
||
|
||
---
|
||
|
||
## Rack Physical and Wiring
|
||
|
||
| hostname | switch | ipmi | oob | oobname | pwr | rack | |
|
||
| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ------- | -------------------|
|
||
| o2.dfw.rg.net | sw0.35 | | 1.8 | o2 | | | Cyclades® ACS-48 |
|
||
| [equnix IX fiber] | 0.46 | | | | | | |
|
||
| r1.dfw.rg.net.2/2/0 | 0.07 | | 2.15 | r1 | | 0.13-17 | LAN |
|
||
| r1.dfw.rg.net.2/2/1 | 2.03 | | 2.15 | r2 | | 0.13-17 | NTT (VLAN 53) |
|
||
| r2.dfw.rg.net-0/0/1/0 | 2.05 | 0.08 | 2.3 | r2 | | 0.18.19 | NTT VLAN 50 |
|
||
| r2.dfw.rg.net.0/1/1 | 2.06 | | 2.3 | | | 0.18.19 | LAN |
|
||
| sw0.dfw.rg.net | 2.47 | | 2.13 | sw0 | | 0.28 | Cicso 2960 |
|
||
| sw2.dfw.rg.net | 0.47 | | 2.02 | sw2 | [^1 ^2] | 0.30 | Cisco 3064 |
|
||
| raid0.dfw.rg.net | [^2] | 0.32 | 2.44 | raid0 | 0.5/1.5 | 0.36-38 | |
|
||
| vm0.dfw.rg.net | 2.25 2.26(drbd) | 2.20 | 2.5 | vm0.dfw | pwr0b B1-11 pwr0r B1-9 | 0.40 | SuperMicro |
|
||
| vm1.dfw.rg.net | 2.27 2.28(drbd) | 2.19 | 2.6 | vm1.dfw | pwr0b B1-10 pwr0r B1-10 | 0.41 | SuperMicro |
|
||
| vm2.dfw.rg.net | 2.23 2.24(drbd) | 2.21 | 2.6 | vm2.dfw | pwr0b B1-09 pwr0r B1-11 | 0.42 | Dell R630 |
|
||
| atlas.dfw.rg.net | 0.33 | | | | vm1.dfw USB | | |
|
||
| | | | | | | | |
|
||
| b0.noc.ietf.org | 3.32 | 3.31 | 2.45 | b0 | pwr1b 18 pwr1r 18 | 1.26 | |
|
||
| sw3.dfw.rg.net | 2.48 | | 2.30 | sw3 | 0.4/1.4 | 1.30 | Cisco 3064 |
|
||
| pwr1.red.dfw.rg.net | 0.41 | | 2.9 | pwr1-red | subfl | 26 | |
|
||
| pwr1.blue.dfw.rg.net | 0.41 | | 2.10 | pwr1-blue | subfl | 26 | |
|
||
| pwr0-blue.dfw.rg.net | 0.42 | | 2.16 | pwr0-blue | subfl | - | |
|
||
| pwr0-red.dfw.rg.net | 0.42 | | 2.17 | pwr0-red | subfl | - | |
|
||
|
||
## Removed
|
||
|
||
| hostname | switch | ipmi | oob | oobname | pwr | rack | |
|
||
| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ------- | -------------------|
|
||
| dallas01.mux.peering.usc.edu | 0.38 | | 2.46 | usc | 0.7/1.7 | 1.40 | |
|
||
| rtcolo.daedalus.com | | xx | 2.45 | b0 | xx | 1.41 | |
|
||
|
||
## Cabling
|
||
|
||
[^1]: RGnet VM servers' ethers are connected to sw2.dfw as follows:
|
||
|
||
| vm | ipmi | e0 | e1 |
|
||
| ---- | ------ | ------ | ------ |
|
||
| vm0 | sw2-20 | sw2-25 | sw2-26 |
|
||
| vm1 | sw2-19 | sw2-27 | sw2-28 |
|
||
| vm2 | sw2-21 | sw2-23 | sw2-24 |
|
||
|
||
[^2]: raid0.dfw ethers are connected to sw2.dfw as follows:
|
||
|
||
| ipmi | e0 | e1 | 10g 0 | 10g 1 |
|
||
| ------ | ------ | ------ | ------ | ------ |
|
||
| sw0-32 | sw2-16 | sw2-17 | sw2-29 | sw2-30 |
|
||
|
||
|
||
## RGnet Cluster / 198.180.152.30 / 198.180.152.7 / 198.180.152.32
|
||
|
||
```
|
||
vm0.dfw.rg.net:/root# qm list
|
||
VMID NAME STATUS MEM(MB) DISK(GB) PID
|
||
111 cats.rg.net running 2048 32.00 21557
|
||
112 cu0.dfw.rg.net running 1024 12.00 368895
|
||
114 mail.rg.net running 2048 32.00 368301
|
||
115 mon0.rg.net running 4096 150.00 367610
|
||
117 wp.rg.net running 2048 64.00 369294
|
||
118 ymbk.com running 1024 16.00 65127
|
||
119 pfs.dfw.rg.net running 1024 8.00 578419
|
||
122 ostrow.rg.net running 2048 32.00 2216835
|
||
vm1.dfw.rg.net:/home/randy> sudo qm list
|
||
VMID NAME STATUS MEM(MB) DISK(GB) PID
|
||
102 git.rg.net running 3072 32.00 118589
|
||
104 netsrv.dfw.rg.net running 2046 100.00 119982
|
||
107 r3.dfw.rg.net running 4096 32.00 121141
|
||
110 baleen.rg.net running 2048 16.00 35309
|
||
113 krill.rg.net running 2048 16.00 34511
|
||
116 routen8or.rg.net running 2048 128.00 33328
|
||
120 a1000006.rg.net running 512 8.00 3380241
|
||
vm2.dfw.rg.net:/home/randy> sudo qm list
|
||
VMID NAME STATUS MEM(MB) DISK(GB) PID
|
||
100 cache0.rg.net running 3072 32.00 807710
|
||
101 ca.rg.net running 5120 128.00 806001
|
||
103 icir.dfw.rg.net running 8192 400.00 423985
|
||
105 nms.rg.net running 2048 80.00 424708
|
||
106 petunia.hactrn.net running 6144 120.00 302667
|
||
108 ran.psg.com running 4096 32.00 321425
|
||
109 wireguard.rg.net running 2048 10.00 325624
|
||
121 m0.rg.net running 2560 32.00 3972
|
||
```
|
||
|
||
## Hosts on vm0/1.dfx.rg.net
|
||
|
||
| Instance | IP_Address | SysAdmin |
|
||
| ------------------- | --------------- | ------------------------------------------ |
|
||
| a1000006.rg.net | 198.180.152.21 | Randy Bush <randy@psg.com> |
|
||
| baleen.rg.net | 198.180.152.61 | Randy Bush <randy@psg.com> |
|
||
| ca.rg.net | 198.180.152.6 | Randy Bush <randy@psg.com> |
|
||
| cache0.rg.net | 198.180.152.33 | Randy Bush <randy@psg.com> |
|
||
| cats.rg.net | 198.180.152.58 | Randy Bush <randy@psg.com> |
|
||
| cu0.dfw.rg.net | 198.180.152.71 | Steven M Bellovin <smb@cs.columbia.edu> John Koh <koh@…> |
|
||
| git.rg.net | 198.180.152.8 | Randy Bush <randy@psg.com> |
|
||
| icir.dfw.rg.net | 198.180.152.57 | Bill Marczak <billmar@gmail.com> |
|
||
| krill.rg.net | 198.180.152.62 | Randy Bush <randy@psg.com> |
|
||
| m0.rg.net | 198.180.152.22 | Randy Bush <randy@psg.com> |
|
||
| mail.rg.net | 198.180.152.11 | Randy Bush <randy@psg.com> |
|
||
| mon0.rg.net | 198.180.152.62 | Randy Bush <randy@psg.com> |
|
||
| netsrv.dfw.rg.net | 198.180.152.15 | Randy Bush <randy@psg.com> |
|
||
| nms.rg.net | 198.180.152.9 | Randy Bush <randy@psg.com> |
|
||
| ostrow.net | 198.180.152.9 | Ari Ostrow <axo193@case.edu> Mark Allman <mallman@icir.org> |
|
||
| petunia.hactrn.net | 198.180.152.200 | Rob Austein <sra@hactrn.net> |
|
||
| pfs.rg.net | 198.180.152.7 | Randy Bush <randy@psg.com> |
|
||
| r3.dfw.rg.net | 198.180.152.93 | Randy Bush <randy@psg.com> |
|
||
| ran.psg.vom | 198.180.152.18 | Randy Bush <randy@psg.com> |
|
||
| routen8or.rg.net | 198.180.152.63 | Randy Bush <randy@psg.com> |
|
||
| wireguard.rg.net | 198.180.152.16 | Hans Kuhn <hans@flyingpoodle.com> |
|
||
| wp.rg.net | 198.180.152.56 | Randy Bush <randy@psg.com> |
|
||
| ymbk.com | 198.180.152.11 | Randy Bush <randy@psg.com> |
|
||
|
||
|
||
## vm0.dfx.rg.net vm1.dfx.rg.net
|
||
VMs are [Supermicro A+ Server 1114S-WTRT Systems](https://www.supermicro.com/Aplus/system/1U/1114/AS-1114S-WTRT.cfm)<br>
|
||
With [Supermicro H12SSW-NT Motherboards](https://www.supermicro.com/en/products/motherboard/H12SSW-NT)<br>
|
||
With one AMD EPYCTM 7443P Single Socket Processor 24-Core 2.85GHz<br>
|
||
With 256G of RAM each<br>
|
||
And 2 Samsung 250GB 970 EVO+ Series - M.2 NVMe PCIe (<1DWPD) (MZ-V7S250B)<br>
|
||
And 8 Samsung 960GB 883 DCT Series - 2.5" SSD SATA 6Gb/s (<1DWPD) (MZ-7LH960NE)<br>
|
||
Serial Numbers: iX1210A-IXN S/N's A1-86827 and A1-86828<br>
|
||
|
||
### vm[0-1].dfx.rg.net Disk Drives
|
||
|
||
```
|
||
vm0.dfx.rg.net:/home/randy# for i in a b c d e f g h; do echo -n "sd$i "; smartctl -a /dev/sd$i | egrep "Serial|Model"; done
|
||
sda Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316039
|
||
sdb Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R107119
|
||
sdc Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316036
|
||
sdd Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316032
|
||
sde Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R303811
|
||
sdf Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316042
|
||
sdg Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R107124
|
||
sdh Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316040
|
||
|
||
vm1.dfx.rg.net:/home/randy# for i in a b c d e f g h; do echo -n "sd$i "; smartctl -a /dev/sd$i | egrep "Serial|Model"; done
|
||
sda Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316035
|
||
sdb Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R303827
|
||
sdc Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316034
|
||
sdd Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R303829
|
||
sde Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R303777
|
||
sdf Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R303803
|
||
sdg Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R303764
|
||
sdh Device Model: SAMSUNG MZ7LH960HAJR-00005
|
||
Serial Number: S45NNA0R316031
|
||
```
|
||
|
||
## vm2.dfw.rg.net
|
||
Dell 630<br>
|
||
Service tag : 6JGVQD2<br>
|
||
2 x E5-2670v3 2.30GHz 12-Core each<br>
|
||
256G RAM<br>
|
||
2 x 10G Ether SFP (eno1 eno2)<br>
|
||
2 x 1G Ether Copper (eno3 eno4)<br>
|
||
H730 RAID<br>
|
||
|
||
## raid0.dfw.rg.net
|
||
|
||
Dell R530<br>
|
||
Service Tag: HQWPW52<br>
|
||
PERC H730P RAID Controller, 2G B NV Cache, Mini card<br>
|
||
2 x 4TB in md0 RAID1 as opsys<br>
|
||
5 x 16TB in zfs<br>
|
||
[System Configuration Page](https://www.dell.com/support/home/en-us/product-support/servicetag/0-V1RMSUVWMzFWOUdxdk5Va1doY2oyQT090/overview)
|
||
|
||
### Drive Bays
|
||
|
||
| | | | |
|
||
| ----- | ----- | ----- | ----- |
|
||
| Bay 0 | Bay 2 | Bay 4 | Bay 6 |
|
||
| Bay 1 | Bay 3 | Bay 5 | Bay 7 |
|
||
|
||
Cable to Bay 5 may be bad 2023.07.16
|
||
|
||
### raid0 Drives
|
||
|
||
`smartctl -a -d megaraid,[0-7] /dev/bus/0`<br>
|
||
Look for smart scan errors with `for i in 0 1 2 3 4 5 6 7; do echo -n "$i "; smartctl -a -d megaraid,$i /dev/bus/0 | grep 'Completed with'; echo; done`
|
||
|
||
| | | | | |
|
||
| --- | --------------- | -------------------- | -------------------- | ----------- |
|
||
| Bay | Manufacturer | Model | Serial ------------ | Installed |
|
||
| 0 | Seagate | ST4000NM0025 | ZC1BBMHX0000C943K87N | 2024.07.28 |
|
||
| 1 | Seagate | ST4000NM0005 | Z4C056KT | 2022.06.06 |
|
||
| 2 | Western Digital | WD161KRYZ-01AGBB0 | 2PH9PMWT | 2022.06.06 |
|
||
| 3 | Western Digital | WD161KRYZ-01AGBB0 | 2PHA0RMT | 2022.06.06 |
|
||
| 4 | Western Digital | WD161KRYZ-01AGBB0 | 2PH9NJNT | 2022.06.06 |
|
||
| 5 | Western Digital | WD161KRYZ-01AGBBO | 2CH669AP | 2023.08.22 |
|
||
| 6 | Seagate | ST16000NM000J-2TW103 | ZR706BX0 | 2022.06.06 |
|
||
|
||
|
||
| 0 | Seagate | ST4000NM0005 | Z4C056TC | 2022.06.06 removed 2024.07.17 |
|
||
| 5 | Western Digital | WD161KRYZ-01AGBB0 | 2PH69HJJ | removed 2023.07.17 |
|
||
|
||
|
||
```
|
||
raid0.dfw.rg.net:/home/randy# for i in 0 1 2 3 4 5 6 7; do echo -n "$i "; smartctl -a -d megaraid,$i /dev/bus/0 | grep 'Serial'; echo; done
|
||
0 Serial number: Z4C056TC
|
||
1 Serial number: Z4C056KT
|
||
2 Serial Number: 2PH9PMWT
|
||
3 Serial Number: 2PHA0RMT
|
||
4 Serial Number: 2PH9NJNT
|
||
5
|
||
6 Serial Number: ZR706BX0
|
||
7 Serial Number: 2PH69HJJ
|
||
```
|
||
|
||
--------
|
||
|
||
## Disgusting Details
|
||
```
|
||
Power
|
||
SO1-A:5C2.2-62/64
|
||
SO2-A:5C2.2-66/68
|
||
SO1-B:5D2.2-62/64
|
||
SO2-B:5D2.2-66/68
|
||
C-Side is Blue and that = "A" feed
|
||
D-Side is Yellow and that = "B" feed
|
||
[ SO2-B:5D2.2-66/68 will not be used ]
|
||
|
||
The demarc for the xconnects is as follows:
|
||
pp01.dfw06
|
||
137-138 M3 Future
|
||
139-140 M4 Future
|
||
141-142 M5 Equinix IX Cable ID #20466027 Terminated on CP:0104:1068601 ports 3/4
|
||
143-144 M6 NTT/Verio r08.dllstx09.us.bb g0/6/0/29
|
||
|
||
Rge Equinix order info for the exchange fiber:
|
||
Ordering contact- Chris Morrow and/or CSM- Shazyra Irizarry
|
||
Technical contact – Randy Bush <randy@psg.com>
|
||
IBX- DA1
|
||
Order: 1-97362053795
|
||
WOA- 3-97445043133 (IX Port Install)
|
||
WOA- 3-97448754941 (NCC Cable install)
|
||
Serial # 20466027 ; terminated on CP:0104:1068601 ports 3/4
|
||
|
||
---
|
||
|
||
Dallas Equinix Colo, Downstairs
|
||
|
||
Google demarc for the riser cable on the Equinix end is Suite 1034 Cage
|
||
00372 Cabinet 105
|
||
|
||
NTT/Verio TDI
|
||
Cage 220, Cab 101 FP#1, Port NA, SMF/SC.
|
||
r08.dllstx09.us.bb g0/6/0/29
|
||
|
||
Media: MMF
|
||
Connector: SC
|
||
|
||
--- ntt circuit ---
|
||
|
||
EQUINIX INC. - Cross Connect Order Complete - 817885.1.1.2
|
||
Completed On: 08-JUN-2009
|
||
IBX: DA1
|
||
Type of Order: Cross Connect
|
||
Cage: DA1::00080:EQUINIX.COM
|
||
Cabinet Number: 0101
|
||
A-Side Patch Panel/Module/Port: PP:0105:2288||1
|
||
Z-Side Customer and Cage Number: YOUTUBE, LLC
|
||
DA1::00372:YOUTUBE
|
||
Z-Side Cabinet Number: 0105
|
||
Carrier Circuit ID(if applicable): EQUINIX SANDBOX
|
||
Z-Side Patch Panel/Module/Port: VP:0105:69862||143
|
||
Cable ID: 1234912
|
||
|
||
EQUINIX INC. - Cross Connect Order Complete - 817885.2.1.2
|
||
Completed On: 05-JUN-2009
|
||
IBX: DA1
|
||
Type of Order: Cross Connect
|
||
Cage: DA1::00080:EQUINIX.COM
|
||
Cabinet Number: 0101
|
||
A-Side Patch Panel/Module/Port: PP:0105:74459||3
|
||
Z-Side Customer and Cage Number: NTT AMERICA, INC.
|
||
DA1::00220:NTT AMERICA, INC. (Verio)
|
||
Z-Side Cabinet Number: 0101
|
||
Carrier Circuit ID(if applicable): EQUINIX SANDBOX
|
||
Z-Side Patch Panel/Module/Port: PP:0101:2375||15
|
||
Cable ID: 1234913
|
||
|
||
For both crossconnects, even though the "Cabinet Number" field shows
|
||
"0101", the actual Equinix A-Side cab is "0105" as listed in the panel
|
||
info. And to reduce cabling and points of failure, the IBX site
|
||
technicians said that they would be connecting both crossconnects
|
||
directly into each other rather than with an intermediate patch cable.
|
||
|
||
--- equinix exchange ---
|
||
|
||
csw7.da1, gig 0/35, Sandbox/RGNet, IX, circuit id 1236454
|
||
```
|
||
|
||
## Routers
|
||
|
||
[]
|
||
|
||
## Tapping BGP Feeds
|
||
|
||
[]
|
||
|
||
|
||
## Old Google PoP
|
||
|
||
We were in Google POP in Via West
|
||
|
||
```
|
||
Viawest/Dataside
|
||
1950 Stemmons Freeway, Suite 2033
|
||
Dallas TX 75027
|
||
+1-214-231-0162
|
||
Mark for "inside delivery"
|
||
|
||
Google PoP DFW06
|
||
Rack Location: 6.3
|
||
Rack: ESW E-00589-01, Black Caster and Mounting Rails, No Door, 7Ft.
|
||
```
|
||
|
||
---
|
||
|
||
## Devices Removed
|
||
|
||
| hostname | switch | ipmi | oob | oobname | pwr | rack | |
|
||
| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ----- | ------------------------------------- |
|
||
| r0.dfw.rg.net-rp0 | 0.45 | | 0.01 | r00 | subfl | 03-13 | |
|
||
| r0.dfw.rg.net-rp0mgt | 0.33 | | | | | 03-13 | |
|
||
| r0.dfw.rg.net-rp1 | 0.?? | | 0.02 | r01 | | 03-13 | |
|
||
| o1.dfw.rg.net | 0.40 | | 0.aux | | 1.1 | 0.22-23 | |
|
||
| r0.dfw.rg.net-rp1mgt | 0.34 | | | | | 03-13 | |
|
||
| [r0.2/0/4 LAN] | 0.04 | | | | | 03-13 | |
|
||
| [r0.2/0/5 ntt fiber] | 0.05 | | | | | 03-13 | |
|
||
| [r0.2/0/6 spare] | 0.06 | | | | | 03-13 | |
|
||
| [r0.2/0/7 equinix ix] | 0.15 | | | | | 03-13 | |
|
||
| sw1.dfw.rg.net | | | 0.13 | sw1 | [^1] | 0.35 | |
|
||
|
||
[^2]: PTSS/B is connected to power 0.2/1.2 and controls both sw0 and sw1
|
||
|
||
|
||
|
||
## DEAD raid0.dfw.rg.net
|
||
|
||
[Mobo Supermicro X7SB4/E](https://www.supermicro.com/products/motherboard/Xeon3000/3210/X7SB4.cfm) [IPMI AOC-IPMI20-E](http://www.supermicro.com/products/accessories/addon/AOC-IPMI20-E.cfm)
|
||
|
||
### raid0 disk drive physical order markings on drive carriers
|
||
|
||
| | | | |
|
||
| ---- | ---- | ---- | ---- |
|
||
| 00 | 10 | 20 | 30 |
|
||
| 01 | 11 | 21 | 31 |
|
||
| 02 | 12 | 22 | 32 |
|
||
| 03 | 13 | 23 | 33 |
|
||
|
||
|
||
```
|
||
for i in 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16; do
|
||
echo -n "1/$i ";
|
||
smartctl -i -d hpt,1/$i /dev/hptrr | grep ^Serial;
|
||
done
|
||
```
|
||
1/1 Serial Number: WD-WMAZA9378538
|
||
1/2 Serial Number: V1KVXSXG
|
||
1/3 Serial Number: YGGU1YTA
|
||
1/4 Serial Number: WD-WMAZA9520754
|
||
1/5 Serial Number: WD-WCAVY0114154
|
||
1/6 Serial Number: WD-WMC5C0D9L6HV
|
||
1/7 Serial Number: WD-WCC6N5UY8H5P
|
||
1/8 Serial Number: WD-WCC300759632
|
||
1/9 Serial Number: WD-WCC6N6DDJ7DT
|
||
1/10 Serial Number: WD-WCC6N6VTE2NF
|
||
1/11 Serial Number: WD-WMC5C0D8Z7FV
|
||
1/12 Serial Number: WD-WMC6N0J6S9AV
|
||
1/13 Serial Number: WD-WCC4MLULA4S4
|
||
1/14 Serial Number: WD-WMC6N0F8FU0U
|
||
1/15 Serial Number: WD-WCAVY0090692
|
||
1/16 Serial Number: WD-WCC6N5CLHYSS
|
||
|
||
| Bay | ID | Drive | Name | Serial Number |
|
||
| ---- | ---- | ----- | --------- | --------------- |
|
||
| 20 | 1/1 | da0 | JBOD-1-1 | WD-WMAZA9378538 |
|
||
| 21 | 1/2 | da1 | JBOD-1-2 | V1KVXSXG |
|
||
| 22 | 1/3 | da2 | JBOD-1-3 | WD-WCC300755734 |
|
||
| 23 | 1/4 | da3 | JBOD-1-4 | WD-WMAZA9520754 |
|
||
| 00 | 1/5 | da4 | JBOD-1-5 | WD-WCAVY0114154 |
|
||
| 01 | 1/6 | da5 | JBOD-1-6 | WD-WMC5C0D9L6HV |
|
||
| 02 | 1/7 | da6 | JBOD-1-7 | WD-WCC6N5UY8H5P |
|
||
| 03 | 1/8 | da7 | JBOD-1-8 | WD-WCC300759632 |
|
||
| 30 | 1/9 | da8 | JBOD-1-9 | WD-WCC6N6DDJ7DT |
|
||
| 31 | 1/10 | da9 | JBOD-1/10 | WD-WCC6N6VTE2NF |
|
||
| 32 | 1/11 | da10 | JBOD-1/11 | WD-WMC5C0D8Z7FV |
|
||
| 33 | 1/12 | da11 | JBOD-1/12 | WD-WMC6N0J6S9AV |
|
||
| 10 | 1/13 | da12 | JBOD-1/13 | WD-WCC4MLULA4S4 |
|
||
| 11 | 1/14 | da13 | JBOD-1/14 | WD-WMC6N0F8FU0U |
|
||
| 12 | 1/15 | da14 | JBOD-1/15 | WD-WCAVY0090692 |
|
||
| 13 | 1/16 | da15 | JBOD-1/16 | WD-WCC6N5CLHYSS |
|
||
|
||
* da1 MK0171YFKMA4AG replaced 2022.05.08
|
||
* da12 MK0171YFKMA59G replaced 2022.04.12
|
||
* da8 WD-WCAVY0111166 replaced 2021.11.22
|
||
* da10 WD-WCAVY0127426 replaced 2016.09.15
|
||
* da1 S2F06GX5 replaced 2016.01.2?
|
||
* da2 WD-WCAVY0112831 replaced 2014.05.12
|
||
* da5 WD-WCAVY0107135 replaced 2017.03.25
|
||
* da13 W1E0B4NJ replaced 2017.06.xx
|
||
* da6 WD-WCAVY0127865 replaced 2018.01.07
|
||
* da6 WD-WMC6N0H8K48M replaced 2021.01.16
|
||
* da9 WD-WCAVY0117958 replaced 2021.03.15
|
||
* da15 WD-WCC4M5VJ4UK3 replaced 2021.06.18
|
||
* da9 WD-WMAY04440674 replaced 2021.08.27
|
||
|
||
## Decommissioned
|
||
|
||
dfw0 1ru compute server SuperMicro SYS-6015W-NTRB w/ X7DWU<br>
|
||
dfw1 3ru big raid server SuperMicro CSE-836TQ-R800B w/ X7SBE<br>
|
||
dfw2 2ru Junosphere virtualization server<br>
|
||
|
||
## DEAD dfw0.psg.com
|
||
|
||
dfw0 drives `for i in 4 5 6 7; do echo /dev/ad$i; smartctl -a /dev/ad$i | egrep 'Model|Serial'; done`
|
||
|
||
| | | | |
|
||
| ---- | ------------------ | ------------ | ---- |
|
||
| Bay | Model | Serial | |
|
||
| | | | |
|
||
| ada0 | ST31000340NS | 9QJ3Q29E | 1TB |
|
||
| ada1 | WD20EADS-00R6B0 | WCAVY0388932 | 2TB |
|
||
| ada2 | WD2005FBYZ-01YCBB1 | WMC6N0F2KZU6 | 2TB |
|
||
| ada3 | ST31000340NS | 9QJ3M5N4 | 1TB |
|
||
| | | | |
|
||
|
||
dfw0 disk drive physical order
|
||
|
||
| ada4 | ada6 | ada5 | ada7 |
|
||
| ---- | ---- | ---- | ---- |
|
||
| ada0 | ada2 | ada1 | ada3 |
|
||
|
||
logical drive labels
|
||
|
||
| label/disk00 | ada0s3 |
|
||
| ------------ | ------ |
|
||
| label/disk01 | ada1s3 |
|
||
| label/disk02 | ada2s1 |
|
||
| label/disk03 | ada3s1 |
|
||
|
||
## DEAD nfs0.dfw.rg.net
|
||
|
||
### MoBo
|
||
* [PDSME+](http://www.supermicro.com/products/motherboard/Xeon3000/3010/PDSME_.cfm)
|
||
* [AOC-SIM1U+ IPMI Card](http://www.supermicro.com/products/accessories/addon/SIM.cfm)
|
||
|
||
### DEAD nfs0.dfw.rg.net Disk Drives
|
||
```
|
||
for i in 0 1 2 3 4 5 6 7; do tw_cli /c2/p$i show serial; done
|
||
```
|
||
|
||
| Port | Model | Serial | Size | Date |
|
||
| -------- | ------------------ | --------------- | ---- | ------------------ |
|
||
| p0 | ST4000DM000-1F2168 | Z300L98C | 4TB | don't know |
|
||
| p1 | WD4000F9YZ-09N20L1 | WD-WCC5D1DS4012 | 4TB | 2019.04.07 |
|
||
| p2 | WD60EFRX-68L0BN1 | WD-WX41DA57H7UJ | 6TB | 2018.03.09 |
|
||
| p3 | WD4000F9YZ-09N20L1 | WD-WCC5D2KHHYE8 | 4TB | 2016.06.09 |
|
||
| p4 | ST4000DM000-1F2168 | Z300KBMM | 4TB | don't know |
|
||
| p5 | ST4000DM000-1F2168 | Z300KBQN | 4TB | don't know |
|
||
| p6 | ST4000DM000-1F2168 | Z300L8J5 | 4TB | don't know |
|
||
| p7 | WD4000F9YZ-09N20L1 | WD-WMC5D0D7V0L9 | 4TB | 2015.12.13 |
|
||
| | | | | |
|
||
| p1 | ST4000DM000-1F2168 | Z300FKES | 4TB | removed 2019.04.07 |
|
||
| p2 | ST4000DM000-1F2168 | Z300L9T3 | 4TB | removed 2018.03.09 |
|
||
| incoming | HUS724040ALS640 | PBK4K70X | 4TB | 2015.12.18 |
|
||
|
||
### Physical Drive layout
|
||
|
||
| | | | |
|
||
| ---- | ---- | ---- | ---- |
|
||
| 4 | 5 | 6 | 7 |
|
||
| 0 | 1 | 2 | 3 |
|
||
|
||
---
|
||