# Seattle KOMO PoP ``` Evocative at KOMO Plaza 140 4th Ave North, Suite 200 Seattle WA 98109 support@evocative.com +1 888 365-2656 (opt 3 is NOC) +1 206 290-9206 (on-site tech) Rack SEF.A.0F.012 ``` Fiber Patch ``` SIX 10G to r2,sea.rg.net A.OF.12.01 OCSX2.A05 MR5A.04.A05 MR5D-09.M06 SIX 1G to r1.sea.rg.net A.OF.12.02 OCSX1.M05 MR5A.02.M05 MR5d.09.C06 SIX 1G to peering.usc.edu A.OF.12.03 OCSX1.M06 MR5A.02.M07 MR5d.09.D06 ``` --- ## KOMO Rack Rack SEF.A.0F.012 Physical Hosts and Wiring | hostname | switch | ipmi | oob | oobname | pwr | rack | Model | | :---------------------------- | ----------- | ----- | ---- | ------- | --------- | ----- | -------------------------------------------------| | sw4.sea.rg.net | s3.47 | | 0.08 | sw4 | 3L 3R | 41 | Cisco Nexus-3064 | | rcuss0.rg.net | s0.23 | N/A | 0.01 | rcuss0 | 4L 4R | 40 | Redstone | | vm3.sea.rg.net | s4.20/s4.22 | s4.18 | ???? | vm3 | 5L 5R | 39 | SuperMicro SuperServer 6019U-TRT | | r2.sea.rg.net | s0.14 s4.36 | | 0.09 | r2 | 6L 6R | 37-38 | Arrcus S9600-72XC-R q2c | | vm4.sea.rg.net | s4.45/s4.46 | s3.5 | 0.13 | NOOP | 9L 9R | 36 | Dell 630 | | vm2.sea.rg.net | s0.41/s0.31 | s0.41 | 0.05 | vm2 | 10L 10R | 34-35 | SuperMicro AS-2022G-URF 2RU Chassis | | psg.com | s0.13 | s0.19 | 0.02 | psg | 7L | 33 | (see below) | | seattle01.mux.peering.usc.edu | s0.11 s0.38 | 0.20 | | | 11R | 31 | Supermicro Ethan Katz-Bassett | | archive.psg.com | vm1.sea.rg.net | vm0.sea.rg.net | 1G | 100G | 147.28.0.8 | Randy Bush | | atlas9.sea.rg.net | vm1.sea.rg.net | | 2G | 16G | 147.28.0.36 | Randy Bush | | atlasvm.sea.rg.net | vm1.sea.rg.net | | 2G | 8G | 147.28.0.33 | Randy Bush | | bbgp.rg.net | vm2.sea.rg.net | | 2G | 32G | 147.28.0.60 | Randy Bush | | build-u.rpki.net | vm1.sea.rg.net | vm2.sea.rg.net | 1G | 100G | 147.28.0.28 | Rob Austein | | cache0.sea.rpki.net | vm2.sea.rg.net | vm0.sea.rg.net | 1G | 100G | 147.28.0.84 | Randy Bush | | chezrandy.x0.dk | vm2.sea.rg.net | | 2G | 200G | 147.28.0.56 | Phil Regnauld | | dataviz.org | vm0.sea.rg.net | vm3sea.rg.net | 8G | 64G | 147.28.0.22 | Randy Bush | | gogs.rg.net | vm3.sea.rg.net | vm2.sea.rg.net | 2G | 64G | 147.28.0.10 | Randy Bush | h| hans.rg.net | vm0.sea.rg.net | vm2.sea.rg.net | 3G | 250G | 147.28.0.42 | Hans Kuhn | | hiroshima.bogus.com | vm1.sea.rg.net | vm0.sea.rg.net | 3G | 250G | 147.28.0.82 | Hans Kuhn | | mon1.rg.net | vm0.sea.rg.net | vm1.sea.rg.net | 4G | 100G | 147.28.0.35 | Randy Bush | | nagasaki.bogus.com | vm0.sea.rg.net | vm1.sea.rg.net | 4G | 250G | 147.28.0.81 | Joel Jaeggli | | netsrv.sea.rg.net | vm4.sea.rg.net | vm1.sea.rg.net | 4G | 200G | 147.28.0.7 | Randy Bush | | nlring.sea.rg.net | vm2.sea.rg.net | vm1.sea.rg.net | 2G | 32G | 147.28.0.89 | Randy Bush | | okui.psg.com | vm0.sea.rg.net | vm1.sea.rg.net | 1G | 1001G | 147.28.0.25 | Patrick Okui | | pfs.sea.rg.net | vm3.sea.rg.net | | 1G | 8G | 147.28.0.32 | Randy Bush | | pws0 | vm1.sea.rg.net | vm2.sea.rg.net | 4G | 100G | 147.28.0.52 | Paul Southworth | | pws1 | vm0.sea.rg.net | vm1.sea.rg.net | 8G | 500G | 147.28.0.53 | Paul Southworth | | r1.securerouting.org | vm1.sea.rg.net | vm2.sea.rg.net | 2G | 100G | 147.28.0.131 | Sam Weiler | | rcuss-build.rg.net | vm3.sea.rg.net | | 64G | 128G | 147.28.0.170 | Rob Austein | | rip.psg.com | vm4.sea.rg.net | vm1.sea.rg.net | 4.0G | 32.1G | 147.28.0.39 | Randy Bush | | rip1.psg.com | vm2.sea.rg.net | vm1.sea.rg.net | 1G | 36G | 147.28.0.31 | Randy Bush | | shout.rg.net | vm1.sea.rg.net | vm2.sea.rg.net | 1G | 16G | 147.28.0.38 | Randy Bush | | tamias.rg.net | vm0.sea.rg.net | vm2.sea.rg.net | 2.0G | 17.0G | 147.28.0.80 | Randy Bush | | turing.sr-ix.com | vm2.sea.rg.net | vm3.sea.rg.net | 2G | 256G | 147.28.0.17 | Tom Jennings | | valid.rg.net | vm0.sea.rg.net | vm2.sea.rg.net | 8G | 200G | 147.28.0.30 | Matthias Wählisch | | vault.sea.rg.net | vm4.sea.rg.net | vm2.sea.rg.net | 1G | 8G | 147.28.0.2 | Randy Bush | | work0.psg.com | vm0.sea.rg.net | | 4G | 100G | 147.28.0.11 | Randy Bush | | xmpp.rg.net | vm1.sea.rg.net | vm0.sea.rg.net | 1G | 34G | 147.28.0.6 | Randy Bush | | zoe.dns.gh | vm4.sea.rg.net | vm0.sea.rg.net | 1G | 200G | 147.28.0.23 | Joel Jaeggli | | zzyzx.sigpipe.org | vm0.sea.rg.net | vm1.sea.rg.net | 2G | 100G | 147.28.0.13 | Michael Elkins | ## vm0.sea.rg.net Hardware - [SuperMicro SuperServer 6018R-MT Chassis](https://www.supermicro.com/products/system/1u/6018/sys-6018r-mt.cfm) - [​SuperMicro X10DRL-i MotherBoard](https://www.supermicro.com/products/motherboard/Xeon/C600/X10DRL-i.cfm) - 2 Intel Xeon E5-2630 V4 2.2 GHz LGA 2011 85W - 128G Kingston ValueRAM 64GB (4 x 16GB) 288-Pin DDR4 SDRAM ECC Registered DDR4 2133 (PC4 17000) Server Memory Model KVR21R15D4K4/64 ### vm0.sea drives, numbered left to right From `for i in a b c d; do smartctl -a /dev/sd$i | egrep 'Model|Serial|Capacity'; done` | Bay | Model | Serial | | | ---- | ------------------ | -------- | ---------- | | 0 | WD6002FFWX-68TZ4N0 | NCGW1TVV | 2016.09.24 | | 1 | WD6002FFWX-68TZ4N0 | NCGWP5SV | 2016.09.24 | | 2 | WD6002FFWX-68TZ4N0 | NCGWD6NV | 2016.09.24 | | 3 | WD6002FFWX-68TZ4N0 | NCGX7MTV | 2016.09.24 | ## vm1.sea.rg.net Hardware **[Cisco R210-2121605W - part 74-7341-02 - serial QCI1549A9AY](http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/data_sheet_c78-587522.html)** - Effectively: 72GB RAM, 4TB datastore1, 8 cores - UCS C210 M2 Svr, 2x E5640, 2x4GB, SAS Expand, 1PS - 2 x 2.66GHz Xeon E5640 80W CPU/12MB cache/DDR3 1066MHz - 4 x 16GB DDR3-1066MHz RDIMM/PC3-8500/quad rank/Low-Dual Volt - 2 x 4GB DDR3-1333MHz RDIMM/PC3-10600/dual rank 1Gb DRAMs - LSI 6G MegaRAID 9261-8i card (RAID 0,1,5,6,10,60) - 512WC - 8 x 500GB 6Gb SATA 7.2K RPM SFF hot plug/drive sled mounted - Intel Quad port GbE Controller (E1G44ETG1P20) ### vm1.sea.rg.net Disk Drives From `megacli -PDList -aALL | egrep 'Coerced|Inquiry'`
also use `sudo smartctl -a -d sat+megaraid,8 /dev/sda`
`megacli -PDList -aall | egrep '^(Slot|Firmware)'` is also useful
`megacli -PDList -aALL | egrep 'Inquiry' | awk '{print $3}' | cut -c1-8` | LUN | Serial | Model | Size | | ---- | -------- | ----------- | -------- | | 01 | 9XF0VD4E | ST9500620NS | 464.7 Gb | | 02 | 9XF21B9B | ST9500620NS | 464.7 Gb | | 03 | 9XF0VCK3 | ST9500620NS | 464.7 Gb | | 04 | 9XF0WE31 | ST9500620NS | 464.7 Gb | | 05 | 9XF1YZBY | ST9500620NS | 464.7 Gb |9XF0WE3J x | 06 | 9XF0TL1A | ST9500620NS | 464.7 Gb |V3FF | 07 | 9XF31KKG | ST9500620NS | 464.7 Gb |VBXF | 08 | 9XF0WDD2 | ST9500620NS | 464.7 Gb |YZBY | 09 | 9XF0VRFD | ST9500620NS | 464.7 Gb |TL1A | 10 | 9XF21BHB | ST9500620NS | 464.7 Gb |1KKG x | 11 | 9XF0WCVD | ST9500620NS | 464.7 Gb |WDD2 | 12 | 9XF0TQ80 | ST9500620NS | 464.7 Gb |VRFD | 13 | S3Z1NB0M | ST9500620NS | 464.7 Gb |1BHB | 14 | S3Z1NB0M | ST9500620NS | 464.7 Gb |WCVD | 15 | 9XF0VDFF | ST9500620NS | 464.7 Gb |TQ80 | 16 | 9XF0VBXF | ST9500620NS | 464.7 Gb |969T x samsung Removed: | 16 | 9XF0VR81 | ST9500620NS | 464.7 Gb | 2022.10.05 | 02 | 9XF0TQ93 | ST9500620NS | 464.7 Gb | 2022.11.17 **[Drive Bays from Cisco Install Manual](https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C210M1/install/C210M1/replace.html)** | | | | | | | ------ | ------ | ------ | ------ | ------ | | | | HDD_01 | HDD_02 | HDD_03 | | | | HDD_04 | HDD_05 | HDD_06 | | HDD_07 | HDD_08 | HDD_09 | HDD_10 | HDD_11 | | HDD_12 | HDD_13 | HDD_14 | HDD_15 | HDD_16 | ## vm2.sea.rg.net Hardware **[SuperMicro AS-2022G-URF 2RU Chassis](http://www.supermicro.com/Aplus/system/2U/2022/AS-2022G-URF.cfm)** - [H8DGU-F Motherboard](http://www.supermicro.com/Aplus/motherboard/Opteron6000/SR56x0/H8DGU-F.cfm) - [Two AMD Opteron 6320 Abu Dhabi 2.8GHz](http://www.amd.com/en-us/products/server/opteron/6000/6300) - [64GB RAMM as two sets of Kingston 32GB (4 x 8GB) 240-Pin DDR3 SDRAM ECC Unbuffered](http://www.kingston.com/us/memory/search/?partid=KVR16E11K4/32) - [32G, two sets of two DIMMs of Crucial Crucial 16GB (2 x 8GB) 240-Pin DDR3 SDRAM ECC Unbuffered DDR3L 1600 (PC3L 12800) Server Memory Model CT2KIT102472BD160B](http://www.crucial.com/usa/en/ct2kit102472bd160b) - [LSI MegaRAID SATA/SAS 9260-8i](http://www.lsi.com/products/raid-controllers/pages/megaraid-sas-9260-8i.aspx) - [Five HGST Ultrastar 7K3000 HUA723020ALA640 (0F12455) 2TB 7200 RPM 64MB Cache SATA 6.0Gb/s](http://www.hgst.com/hard-drives/enterprise-hard-drives/enterprise-sas-drives/ultrastar-7k3000) ### vm2.sea.rg.net Disk Drives ``` vm2.sea.rg.net:/home/randy# megacli -PDList -aALL | egrep '(Slot|^Device Id:|Inquiry)' Slot Number: 0 Device Id: 11 Inquiry Data: WD-WCC6N3FVKC2SWDC WD2002FFSX-68PF8N0 81.00A81 Slot Number: 1 Device Id: 10 Inquiry Data: MK0251YGKB56HAHitachi HUA723020ALA640 MK7OAA10 Slot Number: 2 Device Id: 9 Inquiry Data: MK0251YGKB4N2AHitachi HUA723020ALA640 MK7OAA10 Slot Number: 3 Device Id: 8 Inquiry Data: MK0251YGKB58LAHitachi HUA723020ALA640 MK7OAA10 Slot Number: 4 Device Id: 12 Inquiry Data: MJ1311YNG6XEVAHitachi HDS5C3030ALA630 MEAOA5C0 vm2.sea.rg.net:/home/randy# smartctl -a -d sat+megaraid,11 /dev/sda smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-13-amd64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2002FFSX-68PF8N0 Serial Number: WD-WCC6N3FVKC2S LU WWN Device Id: 5 0014ee 2687b471f Firmware Version: 81.00A81 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Thu Aug 19 20:46:26 2021 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled ``` | LUN | Serial | Model | Size | | ---- | --------------- | ------------------ | -------- | | 0 | WCC6N3FVKC2S | WD2002FFSX-68PF8N0 | 1.818 TB | | 1 | MK0251YGKB56HA | MK7OAA10 | 1.818 TB | | 2 | MK0251YGKB4N2A | MK7OAA10 | 1.818 TB | | 3 | MK0251YGKB58LA | MK7OAA10 | 1.818 TB | | 4 | MJ1311YNG6XEVA | MEAOA5C0 | 2.728 TB | 2021.08.19 LUN0 drive MK0171YFK3TVGA removed ## vm3.sea.rg.net Hardware **[SuperMicro SuperServer 6019U-TRT](https://www.supermicro.com/products/system/1U/6019/SYS-6019U-TRT.cfm)** - [X10DRW-iT Motherboard](https://www.supermicro.com/products/motherboard/Xeon/C600/X10DRW-IT.cfm) - [Two Intel Ten Core 2.4Ghz Xeon 25MB cache 8.0GT/s QPI (90W) (E5-2640v4)](http://ark.intel.com/products/92984/Intel-Xeon-Processor-E5-2640-v4-25M-Cache-2_40-GHz) - 128G RAM - 8x16GB DDR4 2400Mhz 19200 ECC/REG - [Four HGST 6TB Enterprise SATA3 6Gb/s 7200RPM 128MB](https://www.hgst.com/products/hard-drives/ultrastar-7k6000) ### vm3.sea drives, we guess numbered left to right From `for i in a b c d; do smartctl -a /dev/sd$i | egrep 'Model|Serial|Capacity'; done` | Bay | Model | Serial | Capacity | Installed | | ---- | -------------------- | -------------- | -------- | ---------- | | 0 | HGST HUS726060ALE610 | K1J48AGD | 6TB | 2017.08.17 | | 1 | HGST HUS726060ALE610 | K1J2PTND | 6TB | 2017.08.17 | going bad | 2 | HGST HUS726060ALE610 | K8J6HV2N | 6TB | 2022.09.15 | | 3 | HGST HUS726060ALE610 | K1J46RHD | 6TB | 2017.08.17 | replaced: | 2 | HGST HUS726060ALA640 | AR11001EV17LLB | 6TB | 2022.09.15 | for i in b c d e; do echo $i; smartctl -a /dev/sd$i | egrep '(^Serial|Extended)'; done ## vm4.sea.rg.net Hardware - Dell Poweredge R630 Server 2xE5-2640V4 10-core 2.4GHz, 256GB RAM, H730 - Service tag: 6TL7MN2 - Express Service Code 14849840990 - [How to configure the DELL PERC H700/H710/H730/H730P RAID controller](https://www.scaleway.com/en/docs/dedibox/hardware/how-to/configure-dell-perc-h700/) | Bay | Model | Serial | Capacity | Installed | | ---- | ----------------------- | ---------------- | -------- | ---------- | | a | Samsung SSD 870 EVO 2TB | S6PNNL0T909370N | 2TB | 22.11.18 | | b | Samsung SSD 870 EVO 2TB | S6PNNL0T909374Z | 2TB | 22.11.18 | | c | Samsung SSD 870 EVO 2TB | S6PNNL0T708760T | 2TB | 22.11.18 | | d | Samsung SSD 870 EVO 2TB | S6PNNL0T906382W | 2TB | 22.11.18 | ## vm5.sea.rg.net (vm1 Replacement) * Dell Poweredge R640 server * Service Tag: CQPCHQ2 * 2x 10-Core 2.20 GHz Intel CPU's Installed (Silver 4114) * 192GB DDR4 (6x32GB) memory installed * H730P Mini RAID controller. * 4 x Samsung 4TB EVO 870 SSDs * 2x power supplies, 750W each, 100-240V * 4x Gigabit RJ45 NIC network ports TODO: ip addressing /etc/network/INT 147.28.0.46 IPMI config 147.28.0.245 x cmos power on start x periodic local x backup ?? grub prefer video for i in a b c d; do echo $i; smartctl -a /dev/sd$i | egrep '(^Serial|Extended)'; done | Bay | Model | Serial | Capacity | Installed | | ---- | ----------------------- | ---------------- | -------- | ---------- | | a | Samsung SSD 870 EVO 4TB | S6PJNS0W307070P | 4TB | 23.05.21 | | b | Samsung SSD 870 EVO 4TB | S6PJNS0W307067B | 4TB | 23.05.21 | | c | Samsung SSD 870 EVO 4TB | S6PJNS0W307069T | 4TB | 23.05.21 | | d | Samsung SSD 870 EVO 4TB | S6PJNS0W307064R | 4TB | 23.05.21 | ## psg.com [SUPERMICRO AS-1012G-MTF 1U Rackmount](http://www.supermicro.com/Aplus/system/1U/1012/AS-1012G-MTF.cfm) [H8SGL-F mobo](http://www.supermicro.com/Aplus/motherboard/Opteron6000/SR56x0/H8SGL-F.cfm) From `for i in 0 1 2 3 4; do smartctl -a /dev/ada$i | egrep 'Model|Serial|Capacity'; done` | LUN | Model | Serial | Size | | ---- | ---------------------- | --------------- | ---- | | 0 | WDC WD2000F9YZ-09N20L0 | WD-WCC1P0469969 | 2TB | | 1 | WDC WD2005FBYZ-01YCBB1 | WD-WMC6N0F1F8SD | 2TB | WDC WD2000F9YZ-09N20L0 WD-WCC1P0648270 removed from ata1 2017.04.09 WD-WCC1P0654846 replaced on 2017.03.04 ## raid0.sea.rg.net - [5018R-WR Chassis + MoBo](https://www.supermicro.com/products/system/1u/5018/sys-5018r-wr.cfm) - [X10SRW-F Motherboard](https://www.supermicro.com/products/motherboard/Xeon/C600/X10SRW-F.cfm) - [Intel Xeon® Processor E5-2609 v4](https://ark.intel.com/products/92990/Intel-Xeon-Processor-E5-2609-v4-20M-Cache-1-70-GHz-) - Samsung DDR4 2133MHzCL15 16GB RegECC 2Rx4 (PC4 2133) Internal Memory M393A2G40DB0-CPB - FreeBSD USB key left in USB port ### raid0.sea.rg.net Drive Bays From `for i in {0..3}; do smartctl -a /dev/ada$i | egrep 'Model|Serial|Capacity'; done` | LUN | Model | Serial | Capacity | Date | | ---- | -------------------- | --------------- | -------- | ---------- | | 0 | WDC WD60EFRX-68L0BN1 | WD-WX41DA5F88N9 | 6tb | 2018.12.09 | | 1 | WDC WD60EFRX-68L0BN1 | WD-WX11D363T2Y5 | 6tb | 2018.12.09 | | 2 | WDC WD60EFRX-68L0BN1 | WD-WX11D3678XTL | 6tb | 2018.12.09 | | 3 | WDC WD60EFRX-68L0BN1 | WD-WX41D75LN9KC | 6tb | 2018.12.09 | ## Switches | name | mfr | model | ip sddress | | -------------- | ----- | -------------------- | ------------ | | sw0.sea.rg.net | Cisco | WS-C3750G-48PS | 147.28.0.253 | | sw3.sea.rg.net | Cisco | Nexus3064 48x10GE +4 | 147.28.0.239 | | sw4.sea.rg.net | Cisco | Nexus3064 48x10GE +4 | 147.28.0.238 | ### Removed | sw1.sea.rg.net | SMC | SMC8024L2 | 147.28.0.252 | | -------------- | ----- | -------------- | ------------ | | sw2.sea.rg.net | Cisco | WS-C3750G-24PS | 147.28.0.246 | ## Miscelaneous Data ### Spare Drives | | | | | | ---------------- | ------------ | -------- | ---- | | spares in westin | | | | | | | | | | HGST | H3D30003254S | YNG1E3ZC | 3TB | | Seagate | ST31000528AS | 6VPCVN1Y | 1TB | | Seagate | ST3750640A8 | 3QD06D5B | 750G | | HGST | 118032816 | YFJLBZ5A | 2TB | ### r1.sea gigether pic left to right | port | to | medium | | -------- | ------ | --------- | | ge-0/0/0 | LAN | copper | | ge-0/0/1 | six | fiber sfp | | | unused | copper sfp| | | unused | | ## Router Topology [![230428.seattle.jpg](../pics/230428.seattle.jpg)] ## New Switching [![180802.arrcus-sea.jpg](../pics/180802.arrcus-sea.jpg)] ## Old Lunavi Info Lunavi 2001 6th Avenue, Suite 2402 Seattle, WA 98121 Lunavi Support 206 777 9988 24x7@ccom.net 206-854-3444 and 206-353-5558 --- 2023.06.04