diff --git a/pages/221028.ashburn.jpg b/pages/221028.ashburn.jpg deleted file mode 100644 index 9c55b1f..0000000 Binary files a/pages/221028.ashburn.jpg and /dev/null differ diff --git a/pages/SeattleKOMOPoP.md b/pages/SeattleKOMOPoP.md index 1367df3..effa0d6 100644 --- a/pages/SeattleKOMOPoP.md +++ b/pages/SeattleKOMOPoP.md @@ -39,23 +39,23 @@ Physical Hosts and Wiring | hostname | switch | ipmi | oob | oobname | pwr | rack | Model | | :---------------------------- | ----------- | ----- | ---- | ------- | --------- | ----- | -------------------------------------------------| -| sw4.sea.rg.net | s3.47 | | 0.08 | sw4 | 1.1 | 41 | Cisco Nexus-3064 | -| rcuss0.rg.net | s0.23 | N/A | 0.01 | rcuss0 | 1.2 | 40 | Redstone | -| vm3.sea.rg.net | s4.20/s4.22 | s4.18 | ???? | vm3 | 0.2 | 39 | SuperMicro SuperServer 6019U-TRT | -| r2.sea.rg.net | s0.14 s4.36 | | 0.09 | r2 | 1.7 | 37-38 | Arrcus S9600-72XC-R q2c | -| vm4.sea.rg.net | s4.45/s4.46 | s3.5 | 0.13 | NOOP | 1.3 | 36 | Dell 630 | -| vm2.sea.rg.net | s0.41/s0.31 | s0.41 | 0.05 | vm2 | 2.7 2.1 | 34-35 | SuperMicro AS-2022G-URF 2RU Chassis | -| psg.com | s0.13 | s0.19 | 0.02 | psg | 1.5 | 33 | (see below) | -| seattle01.mux.peering.usc.edu | s0.11 s0.38 | 0.20 | | | | 31 | Supermicro Ethan Katz-Bassett | 02 | 9XF21B9B | ST9500620NS | 464.7 Gb | | 03 | 9XF0VCK3 | ST9500620NS | 464.7 Gb | | 04 | 9XF0WE31 | ST9500620NS | 464.7 Gb | -| 05 | 9XF1YZBY | ST9500620NS | 464.7 Gb | -| 06 | 9XF0TL1A | ST9500620NS | 464.7 Gb | -| 07 | 9XF31KKG | ST9500620NS | 464.7 Gb | -| 08 | 9XF0WDD2 | ST9500620NS | 464.7 Gb | -| 09 | 9XF0VRFD | ST9500620NS | 464.7 Gb | -| 10 | 9XF21BHB | ST9500620NS | 464.7 Gb | -| 11 | 9XF0WCVD | ST9500620NS | 464.7 Gb | -| 12 | 9XF0TQ80 | ST9500620NS | 464.7 Gb | -| 13 | S3Z1NB0M | ST9500620NS | 464.7 Gb | -| 14 | S3Z1NB0M | ST9500620NS | 464.7 Gb | -| 15 | 9XF0VDFF | ST9500620NS | 464.7 Gb | -| 16 | 9XF0VBXF | ST9500620NS | 464.7 Gb | +| 05 | 9XF1YZBY | ST9500620NS | 464.7 Gb |9XF0WE3J x +| 06 | 9XF0TL1A | ST9500620NS | 464.7 Gb |V3FF +| 07 | 9XF31KKG | ST9500620NS | 464.7 Gb |VBXF +| 08 | 9XF0WDD2 | ST9500620NS | 464.7 Gb |YZBY +| 09 | 9XF0VRFD | ST9500620NS | 464.7 Gb |TL1A +| 10 | 9XF21BHB | ST9500620NS | 464.7 Gb |1KKG x +| 11 | 9XF0WCVD | ST9500620NS | 464.7 Gb |WDD2 +| 12 | 9XF0TQ80 | ST9500620NS | 464.7 Gb |VRFD +| 13 | S3Z1NB0M | ST9500620NS | 464.7 Gb |1BHB +| 14 | S3Z1NB0M | ST9500620NS | 464.7 Gb |WCVD +| 15 | 9XF0VDFF | ST9500620NS | 464.7 Gb |TQ80 +| 16 | 9XF0VBXF | ST9500620NS | 464.7 Gb |969T x samsung Removed: | 16 | 9XF0VR81 | ST9500620NS | 464.7 Gb | 2022.10.05 @@ -342,6 +342,49 @@ replaced: for i in b c d e; do echo $i; smartctl -a /dev/sd$i | egrep '(^Serial|Extended)'; done +## vm4.sea.rg.net Hardware + +- Dell Poweredge R630 Server 2xE5-2640V4 10-core 2.4GHz, 256GB RAM, H730 +- Service tag: 6TL7MN2 +- Express Service Code 14849840990 +- [How to configure the DELL PERC H700/H710/H730/H730P RAID controller](https://www.scaleway.com/en/docs/dedibox/hardware/how-to/configure-dell-perc-h700/) + +| Bay | Model | Serial | Capacity | Installed | +| ---- | ----------------------- | ---------------- | -------- | ---------- | +| a | Samsung SSD 870 EVO 2TB | S6PNNL0T909370N | 2TB | 22.11.18 | +| b | Samsung SSD 870 EVO 2TB | S6PNNL0T909374Z | 2TB | 22.11.18 | +| c | Samsung SSD 870 EVO 2TB | S6PNNL0T708760T | 2TB | 22.11.18 | +| d | Samsung SSD 870 EVO 2TB | S6PNNL0T906382W | 2TB | 22.11.18 | + +## vm5.sea.rg.net (vm1 Replacement) + +* Dell Poweredge R640 server +* Service Tag: CQPCHQ2 +* 2x 10-Core 2.20 GHz Intel CPU's Installed (Silver 4114) +* 192GB DDR4 (6x32GB) memory installed +* H730P Mini RAID controller. +* 4 x Samsung 4TB EVO 870 SSDs +* 2x power supplies, 750W each, 100-240V +* 4x Gigabit RJ45 NIC network ports + +TODO: +ip addressing /etc/network/INT 147.28.0.46 +IPMI config 147.28.0.245 +x cmos power on start +x periodic local +x backup +?? grub prefer video + +for i in a b c d; do echo $i; smartctl -a /dev/sd$i | egrep '(^Serial|Extended)'; done + +| Bay | Model | Serial | Capacity | Installed | +| ---- | ----------------------- | ---------------- | -------- | ---------- | +| a | Samsung SSD 870 EVO 4TB | S6PJNS0W307070P | 4TB | 23.05.21 | +| b | Samsung SSD 870 EVO 4TB | S6PJNS0W307067B | 4TB | 23.05.21 | +| c | Samsung SSD 870 EVO 4TB | S6PJNS0W307069T | 4TB | 23.05.21 | +| d | Samsung SSD 870 EVO 4TB | S6PJNS0W307064R | 4TB | 23.05.21 | + + ## psg.com [SUPERMICRO AS-1012G-MTF 1U Rackmount](http://www.supermicro.com/Aplus/system/1U/1012/AS-1012G-MTF.cfm) [H8SGL-F mobo](http://www.supermicro.com/Aplus/motherboard/Opteron6000/SR56x0/H8SGL-F.cfm) @@ -357,14 +400,6 @@ WDC WD2000F9YZ-09N20L0 WD-WCC1P0648270 removed from ata1 2017.04.09 WD-WCC1P0654846 replaced on 2017.03.04 -## vm4.sea.rg.net Hardware - -- Dell Poweredge R630 Server 2xE5-2640V4 10-core 2.4GHz, 256GB RAM, H730 -- Service tag: 6TL7MN2 -- Express Service Code 14849840990 -- [How to configure the DELL PERC H700/H710/H730/H730P RAID controller](https://www.scaleway.com/en/docs/dedibox/hardware/how-to/configure-dell-perc-h700/) - - ## raid0.sea.rg.net - [5018R-WR Chassis + MoBo](https://www.supermicro.com/products/system/1u/5018/sys-5018r-wr.cfm) @@ -442,4 +477,4 @@ Lunavi Support --- -2023.05.08 +2023.06.04 diff --git a/pages/SeattleWastinPoP.md b/pages/SeattleWastinPoP.md deleted file mode 100644 index 0127236..0000000 --- a/pages/SeattleWastinPoP.md +++ /dev/null @@ -1,570 +0,0 @@ -# Seattle KOMO PoP - -``` -Evocative at KOMO Plaza -140 4th Ave North, Suite 200 -Seattle WA 98109 -support@evocative.com -+1 888 365-2656 (opt 3 is NOC) -+1 206 290-9206 (on-site tech) - -Rack SEF.A.0F.012 -``` - -Fiber Patch -``` -SIX 10G to r2,sea.rg.net - A.OF.12.01 - OCSX1.M04 - MR5A.02.M04 - MR5d.09.B06 - -SIX 1G to peering.usc.edu - A.OF.12.02 - OCSX1.M05 - MR5A.02.M05 - MR5d.09.C06 - -SIX 1G to r1.sea.rg.net - A.OF.12.03 - OCSX1.M06 - MR5A.02.M07 - MR5d.09.D06 -``` ---- - -## KOMO Rack -Rack SEF.A.0F.012 -Physical Hosts and Wiring - -| hostname | switch | ipmi | oob | oobname | pwr | rack | Model | -| :---------------------------- | ----------- | ----- | ---- | ------- | --------- | ----- | ----------------------------------------------------- | -| sw4.sea.rg.net | s3.47 | | 0.08 | sw4 | 1.1 | 41 | Cisco Nexus-3064 | -| rcuss0.rg.net | s0.23 | N/A | 0.01 | rcuss0 | 1.2 | 40 | Redstone | -| vm3.sea.rg.net | s4.20/s4.22 | s4.18 | ???? | vm3 | 0.2 | 39 | SuperMicro SuperServer 6019U-TRT | -| r2.sea.rg.net | s0.14 s4.36 | | 0.09 | r2 | 1.7 | 37-38 | Arrcus xxx q2c aka sixa.rg.net | -| vm4.sea.rg.net | s4.45/s4.46 | s3.5 | 0/13 | ??? | 1.3 | 36 | Dell 630 | -| vm2.sea.rg.net | s0.41/s0.31 | s0.41 | 0.05 | vm2 | 2.7 2.1 | 34-35 | SuperMicro AS-2022G-URF 2RU Chassis | -| psg.com | s0.13 | s0.19 | 0.02 | psg | 1.5 | 33 | (see below) | -| seattle01.mux.peering.usc.edu | s0.11 s0.38 | 0.20 | | | | 31 | Supermicro Ethan Katz-Bassett | -| sw3.sea.rg.net | s0.47 | | 0.07 | sw3 | 0.7 | 27 | Cisco Nexus-3064 | -| sw0.sea.rg.net | s3.48 | | 0.06 | sw0 | 0.4 | 26 | Cisco WS-C3750G-POE-48 | -| atlas0.sea.rg.net | s0.25 | | | | | 20.5 | Atlas v0 Probe | -| raid0.sea.rg.net | s0.27 | s0.03 | 0.12 | raid0 | 0.6 | 19 | SuperMicro 5018R-WR | -| o0.sea.rg.net | s0.06 | | | | 2.4 | 18 | Cyclades ACS-48 | -| vm1.sea.rg.net | s0.34/s0.30 | s0.33 | 0.04 | vm1 | 0.2 | 16-17 | (see below) | -| vm0.sea.rg.net | s0.26/s0.29 | s0.39 | 0.03 | vm0 | 2.5/2.7 | 15 | Supermicro - w/ X7DWU | -| r0.sea.rg.net | s0.35/46 | | 0.11 | r0 | 0.8 & 3.7 | 7 | Cisco ASR1001 commissioned 2018.02.02 | -| r1.sea.rg.net | s0.17 | | 0.10 | r1 | 2.1 & 3.1 | 5-6 | Juniper M7i | -| pwr0.sea.rg.net | s0.12 | | | | | L | APC AP7930 | -| pwr1.sea.rg.net | s0.16 | | | | | R | APC AP7930 | - ---- - -## pwr0 and pr41 MACs - -| name | side | model | MAC | -| :--- | ------ | ------- | ----------------- | -| pwr0 | left | AP7930 | 00:C0:B7:C8:49:BC | -| pwr0 | right | AP7930 | 00:C0:B7:30:1C:16 | - -## 100mb interfaces on sw0 -* atlas probe -* o0.sea.rg.net -* four power bars -* psg.com ipmi -* peering.usc.edu ipmi -* ipmi.vm1.sea.rg.net -* ipmi.vm0.sea.rg.net -* pwr0.sea.rg.net -* pwr1.sea.rg.net - ---- - -## vm[0-3].sea.rg.net Ganeti Cluster - -``` -vm4.sea.rg.net:/root# ./do-stat -Node DTotal DFree MTotal MNode MFree Pinst Sinst -vm0.sea.rg.net 10.9T 6.9T 125.8G 89.7G 90.2G 9 10 -vm1.sea.rg.net 5.9T 2.3T 70.7G 38.1G 53.3G 10 11 -vm2.sea.rg.net 5.5T 4.1T 94.4G 23.4G 79.6G 8 5 -vm3.sea.rg.net 10.9T 7.1T 503.8G 59.0G 431.3G 3 0 -vm4.sea.rg.net 3.6T 2.2T 251.8G 67.0G 234.6G 5 0 - -Instance Primary_node Secondary_Nodes Disk/0 Memory ConfigVCPUs -adrilankha.hactrn.net vm1.sea.rg.net vm0.sea.rg.net 260.0G 4.0G 1 -archive.psg.com vm1.sea.rg.net vm0.sea.rg.net 200.0G 2.0G 1 -atlas9.sea.rg.net vm1.sea.rg.net 16.0G 2.0G 1 -atlasvm.sea.rg.net vm1.sea.rg.net 8.0G 2.0G 1 -bbgp.rg.net vm2.sea.rg.net 32.0G 2.0G 1 -build-u.rpki.net vm1.sea.rg.net vm2.sea.rg.net 100.0G 1.0G 1 -cache0.sea.rpki.net vm2.sea.rg.net vm0.sea.rg.net 100.0G 2.0G 1 -chezrandy.x0.dk vm2.sea.rg.net 300.0G 2.0G 1 -dataviz.org vm0.sea.rg.net vm1.sea.rg.net 64.0G 8.0G 1 -dnsexp.rg.net vm2.sea.rg.net 32.0G 1.0G 1 -gogs.rg.net vm3.sea.rg.net 65.0G 2.0G 1 -hans.rg.net vm4.sea.rg.net vm0.sea.rg.net 251.0G 4.0G 1 -hiroshima.bogus.com vm1.sea.rg.net vm0.sea.rg.net 250.0G 2.0G 1 -jitsi.rg.net vm1.sea.rg.net vm0.sea.rg.net 32.0G 2.0G 1 -mon1.rg.net vm0.sea.rg.net vm1.sea.rg.net 100.0G 4.0G 1 -nagasaki.bogus.com vm0.sea.rg.net vm1.sea.rg.net 250.0G 4.0G 1 -netsrv.sea.rg.net vm4.sea.rg.net vm1.sea.rg.net 210.0G 1.0G 1 -nlring.sea.rg.net vm2.sea.rg.net vm1.sea.rg.net 32.0G 2.0G 1 -okui.psg.com vm0.sea.rg.net vm1.sea.rg.net 1001.0G 1.0G 1 -pfs.sea.rg.net vm3.sea.rg.net 8.0G 1.0G 1 -pws0 vm2.sea.rg.net vm1.sea.rg.net 100.0G 4.0G 1 -pws1 vm0.sea.rg.net vm1.sea.rg.net 500.0G 8.0G 1 -r1.securerouting.org vm1.sea.rg.net vm2.sea.rg.net 100.0G 2.0G 1 -rcuss-build.rg.net vm3.sea.rg.net 316.0G 64.0G 16 -rip1.psg.com vm2.sea.rg.net vm1.sea.rg.net 36.0G 4.0G 1 -rip.psg.com vm4.sea.rg.net vm1.sea.rg.net 32.0G 8.0G 2 -shout.rg.net vm1.sea.rg.net vm0.sea.rg.net 16.0G 1.0G 1 -tamias.rg.net vm0.sea.rg.net vm2.sea.rg.net 17.0G 2.0G 1 -turing.sr-ix.com vm2.sea.rg.net vm0.sea.rg.net 256.0G 2.0G 1 -valid.rg.net vm0.sea.rg.net vm2.sea.rg.net 200.0G 8.0G 1 -vault.sea.rg.net vm4.sea.rg.net vm2.sea.rg.net 8.0G 1.0G 1 -work0.psg.com vm0.sea.rg.net 200.0G 4.0G 1 -xmpp.rg.net vm1.sea.rg.net vm0.sea.rg.net 33.0G 1.0G 1 -zoe.dns.gh vm4.sea.rg.net vm0.sea.rg.net 32.0G 1.0G 1 -zzyzx.sigpipe.org vm0.sea.rg.net vm1.sea.rg.net 100.0G 2.0G 1 -``` - -isovalent - -### BackChannel -net 10, drdb Ports for vm[0-4] - -| Switch | Port | Host | Ether | IP Address | -| ------ | ---- | ------- | ----- | ---------- | -| sw0 | 29 | vm0.sea | eth1 | 10.0.0.100 | -| sw0 | 30 | vm1.sea | eth5 | 10.0.0.101 | -| sw0 | 31 | vm2.sea | eth1 | 10.0.0.102 | -| sw4 | 22 | vm3.sea | eth1 | 10.0.0.103 | -| sw4 | 46 | vm4.sea | enp130s0f1 | 10.0.0.104 | - -### Guest VMs on vm0/1/2/3.sea.rg.net / 147.28.0.14/15/16/29 - -`gnt-instance list -o "name,pnode,snodes,be/memory,disk.size/0"` - -| Instance | Primary_node | Secondary_Node | MaxMem | DiskUsage | IP_Address | SysAdmin | -| --------------------- | -------------- | -------------- | ------ | --------- | ------------ | --------------------------------- | -| adrilankha.hactrn.net | vm1.sea.rg.net | vm0.sea.rg.net | 4G | 260G | 147.28.0.19 | Rob Austein | -| archive.psg.com | vm1.sea.rg.net | vm0.sea.rg.net | 1G | 100G | 147.28.0.8 | Randy Bush | -| atlas9.sea.rg.net | vm1.sea.rg.net | | 2G | 16G | 147.28.0.36 | Randy Bush | -| atlasvm.sea.rg.net | vm1.sea.rg.net | | 2G | 8G | 147.28.0.33 | Randy Bush | -| bbgp.rg.net | vm2.sea.rg.net | | 2G | 32G | 147.28.0.60 | Randy Bush | -| build-u.rpki.net | vm1.sea.rg.net | vm2.sea.rg.net | 1G | 100G | 147.28.0.28 | Rob Austein | -| cache0.sea.rpki.net | vm2.sea.rg.net | vm0.sea.rg.net | 1G | 100G | 147.28.0.84 | Randy Bush | -| chezrandy.x0.dk | vm2.sea.rg.net | | 2G | 200G | 147.28.0.56 | Phil Regnauld | -| dataviz.org | vm0.sea.rg.net | vm3sea.rg.net | 8G | 64G | 147.28.0.22 | Randy Bush | -| gogs.rg.net | vm3.sea.rg.net | vm2.sea.rg.net | 2G | 64G | 147.28.0.10 | Randy Bush | -| hans.rg.net | vm0.sea.rg.net | vm2.sea.rg.net | 3G | 250G | 147.28.0.42 | Hans Kuhn | -| hiroshima.bogus.com | vm1.sea.rg.net | vm0.sea.rg.net | 3G | 250G | 147.28.0.82 | Hans Kuhn | -| mon1.rg.net | vm0.sea.rg.net | vm1.sea.rg.net | 4G | 100G | 147.28.0.35 | Randy Bush | -| nagasaki.bogus.com | vm0.sea.rg.net | vm1.sea.rg.net | 4G | 250G | 147.28.0.81 | Joel Jaeggli | -| netsrv.sea.rg.net | vm1.sea.rg.net | vm2.sea.rg.net | 1G | 200G | 147.28.0.7 | Randy Bush | -| nlring.sea.rg.net | vm2.sea.rg.net | vm1.sea.rg.net | 2G | 32G | 147.28.0.89 | Randy Bush | -| okui.psg.com | vm0.sea.rg.net | vm1.sea.rg.net | 1G | 1001G | 147.28.0.25 | Patrick Okui | -| pfs.sea.rg.net | vm3.sea.rg.net | | 1G | 8G | 147.28.0.32 | Randy Bush | -| pws0 | vm2.sea.rg.net | vm1.sea.rg.net | 4G | 100G | 147.28.0.52 | Paul Southworth | -| pws1 | vm1.sea.rg.net | vm0.sea.rg.net | 8G | 500G | 147.28.0.53 | Paul Southworth | -| r1.securerouting.org | vm1.sea.rg.net | vm2.sea.rg.net | 2G | 100G | 147.28.0.131 | Sam Weiler | -| rcuss-build.rg.net | vm3.sea.rg.net | | 64G | 128G | 147.28.0.170 | Rob Austein | -| rip.psg.com | vm3.sea.rg.net | vm2.sea.rg.net | 4.0G | 32.1G | 147.28.0.39 | Randy Bush | -| rip1.psg.com | vm2.sea.rg.net | vm1.sea.rg.net | 1G | 36G | 147.28.0.31 | Randy Bush | -| shout.rg.net | vm1.sea.rg.net | vm2.sea.rg.net | 1G | 16G | 147.28.0.38 | Randy Bush | -| tamias.rg.net | vm0.sea.rg.net | vm2.sea.rg.net | 2.0G | 17.0G | 147.28.0.80 | Randy Bush | -| turing.sr-ix.com | vm2.sea.rg.net | vm3.sea.rg.net | 2G | 256G | 147.28.0.17 | Tom Jennings | -| valid.rg.net | vm0.sea.rg.net | vm2.sea.rg.net | 8G | 200G | 147.28.0.30 | Matthias Wählisch | -| vault.sea.rg.net | vm3.sea.rg.net | vm2.sea.rg.net | 1G | 8G | 147.28.0.2 | Randy Bush | -| work0.psg.com | vm0.sea.rg.net | | 4G | 100G | 147.28.0.11 | Randy Bush | -| xmpp.rg.net | vm1.sea.rg.net | vm3.sea.rg.net | 1G | 34G | 147.28.0.6 | Randy Bush | -| zoe.dns.gh | vm2.sea.rg.net | vm1.sea.rg.net | 1G | 200G | 147.28.0.23 | Joel Jaeggli | -| zzyzx.sigpipe.org | vm0.sea.rg.net | vm1.sea.rg.net | 2G | 100G | 147.28.0.13 | Michael Elkins | - -## vm0.sea.rg.net Hardware - -- [SuperMicro SuperServer 6018R-MT Chassis](https://www.supermicro.com/products/system/1u/6018/sys-6018r-mt.cfm) -- [​SuperMicro X10DRL-i MotherBoard](https://www.supermicro.com/products/motherboard/Xeon/C600/X10DRL-i.cfm) - -- 2 Intel Xeon E5-2630 V4 2.2 GHz LGA 2011 85W -- 128G Kingston ValueRAM 64GB (4 x 16GB) 288-Pin DDR4 SDRAM ECC Registered DDR4 2133 (PC4 17000) Server Memory Model KVR21R15D4K4/64 - -### vm0.sea drives, numbered left to right - -From `for i in a b c d; do smartctl -a /dev/sd$i | egrep 'Model|Serial|Capacity'; done` - -| Bay | Model | Serial | | -| ---- | ------------------ | -------- | ---------- | -| 0 | WD6002FFWX-68TZ4N0 | NCGW1TVV | 2016.09.24 | -| 1 | WD6002FFWX-68TZ4N0 | NCGWP5SV | 2016.09.24 | -| 2 | WD6002FFWX-68TZ4N0 | NCGWD6NV | 2016.09.24 | -| 3 | WD6002FFWX-68TZ4N0 | NCGX7MTV | 2016.09.24 | - -## vm1.sea.rg.net Hardware - - **[Cisco R210-2121605W - part 74-7341-02 - serial QCI1549A9AY](http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/data_sheet_c78-587522.html)** - -- Effectively: 72GB RAM, 4TB datastore1, 8 cores -- UCS C210 M2 Svr, 2x E5640, 2x4GB, SAS Expand, 1PS -- 2 x 2.66GHz Xeon E5640 80W CPU/12MB cache/DDR3 1066MHz -- 4 x 16GB DDR3-1066MHz RDIMM/PC3-8500/quad rank/Low-Dual Volt -- 2 x 4GB DDR3-1333MHz RDIMM/PC3-10600/dual rank 1Gb DRAMs -- LSI 6G MegaRAID 9261-8i card (RAID 0,1,5,6,10,60) - 512WC -- 8 x 500GB 6Gb SATA 7.2K RPM SFF hot plug/drive sled mounted -- Intel Quad port GbE Controller (E1G44ETG1P20) - -### vm1.sea.rg.net Disk Drives - -From `megacli -PDList -aALL | egrep 'Coerced|Inquiry'`
- also use `sudo smartctl -a -d sat+megaraid,8 /dev/sda`
- `megacli -PDList -aall | egrep '^(Slot|Firmware)'` is also useful
- `megacli -PDList -aALL | egrep 'Inquiry' | awk '{print $3}' | cut -c1-8` - -| LUN | Serial | Model | Size | -| ---- | -------- | ----------- | -------- | -| 01 | 9XF0VD4E | ST9500620NS | 464.7 Gb | -| 02 | 9XF21B9B | ST9500620NS | 464.7 Gb | -| 03 | 9XF0VCK3 | ST9500620NS | 464.7 Gb | -| 04 | 9XF0WE31 | ST9500620NS | 464.7 Gb | -| 05 | 9XF0WEYZ | ST9500620NS | 464.7 Gb | -| 06 | 9XF0VDFF | ST9500620NS | 464.7 Gb | -| 07 | 9XF0VBXF | ST9500620NS | 464.7 Gb | -| 08 | 9XF1YZBY | ST9500620NS | 464.7 Gb | -| 09 | 9XF0TL1A | ST9500620NS | 464.7 Gb | -| 10 | 9XF31KKG | ST9500620NS | 464.7 Gb | -| 11 | 9XF0WDD2 | ST9500620NS | 464.7 Gb | -| 12 | 9XF0VRFD | ST9500620NS | 464.7 Gb | -| 13 | 9XF21BHB | ST9500620NS | 464.7 Gb | -| 14 | 9XF0WCVD | ST9500620NS | 464.7 Gb | -| 15 | 9XF0TQ80 | ST9500620NS | 464.7 Gb | -| 16 | S3Z1NB0M229969T | ST9500620NS | 464.7 Gb | - -Removed: -| 16 | 9XF0VR81 | ST9500620NS | 464.7 Gb | 2022.10.05 -| 02 | 9XF0TQ93 | ST9500620NS | 464.7 Gb | 2022.11.17 - -**[Drive Bays from Cisco Install Manual](https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C210M1/install/C210M1/replace.html)** - -| | | | | | -| ------ | ------ | ------ | ------ | ------ | -| | | HDD_01 | HDD_02 | HDD_03 | -| | | HDD_04 | HDD_05 | HDD_06 | -| HDD_07 | HDD_08 | HDD_09 | HDD_10 | HDD_11 | -| HDD_12 | HDD_13 | HDD_14 | HDD_15 | HDD_16 | - -## vm2.sea.rg.net Hardware - - **[SuperMicro AS-2022G-URF 2RU Chassis](http://www.supermicro.com/Aplus/system/2U/2022/AS-2022G-URF.cfm)** - -- [H8DGU-F Motherboard](http://www.supermicro.com/Aplus/motherboard/Opteron6000/SR56x0/H8DGU-F.cfm) -- [Two AMD Opteron 6320 Abu Dhabi 2.8GHz](http://www.amd.com/en-us/products/server/opteron/6000/6300) -- [64GB RAMM as two sets of Kingston 32GB (4 x 8GB) 240-Pin DDR3 SDRAM ECC Unbuffered](http://www.kingston.com/us/memory/search/?partid=KVR16E11K4/32) -- [32G, two sets of two DIMMs of Crucial Crucial 16GB (2 x 8GB) 240-Pin DDR3 SDRAM ECC Unbuffered DDR3L 1600 (PC3L 12800) Server Memory Model CT2KIT102472BD160B](http://www.crucial.com/usa/en/ct2kit102472bd160b) -- [LSI MegaRAID SATA/SAS 9260-8i](http://www.lsi.com/products/raid-controllers/pages/megaraid-sas-9260-8i.aspx) -- [Five HGST Ultrastar 7K3000 HUA723020ALA640 (0F12455) 2TB 7200 RPM 64MB Cache SATA 6.0Gb/s](http://www.hgst.com/hard-drives/enterprise-hard-drives/enterprise-sas-drives/ultrastar-7k3000) - -### vm2.sea.rg.net Disk Drives - -``` -vm2.sea.rg.net:/home/randy# megacli -PDList -aALL | egrep '(Slot|^Device Id:|Inquiry)' -Slot Number: 0 -Device Id: 11 -Inquiry Data: WD-WCC6N3FVKC2SWDC WD2002FFSX-68PF8N0 81.00A81 -Slot Number: 1 -Device Id: 10 -Inquiry Data: MK0251YGKB56HAHitachi HUA723020ALA640 MK7OAA10 -Slot Number: 2 -Device Id: 9 -Inquiry Data: MK0251YGKB4N2AHitachi HUA723020ALA640 MK7OAA10 -Slot Number: 3 -Device Id: 8 -Inquiry Data: MK0251YGKB58LAHitachi HUA723020ALA640 MK7OAA10 -Slot Number: 4 -Device Id: 12 -Inquiry Data: MJ1311YNG6XEVAHitachi HDS5C3030ALA630 MEAOA5C0 - - -vm2.sea.rg.net:/home/randy# smartctl -a -d sat+megaraid,11 /dev/sda -smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-13-amd64] (local build) -Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org - -=== START OF INFORMATION SECTION === -Device Model: WDC WD2002FFSX-68PF8N0 -Serial Number: WD-WCC6N3FVKC2S -LU WWN Device Id: 5 0014ee 2687b471f -Firmware Version: 81.00A81 -User Capacity: 2,000,398,934,016 bytes [2.00 TB] -Sector Sizes: 512 bytes logical, 4096 bytes physical -Rotation Rate: 7200 rpm -Form Factor: 3.5 inches -Device is: Not in smartctl database [for details use: -P showall] -ATA Version is: ACS-3 T13/2161-D revision 5 -SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) -Local Time is: Thu Aug 19 20:46:26 2021 UTC -SMART support is: Available - device has SMART capability. -SMART support is: Enabled - -``` - -| LUN | Serial | Model | Size | -| ---- | --------------- | ------------------ | -------- | -| 0 | WCC6N3FVKC2S | WD2002FFSX-68PF8N0 | 1.818 TB | -| 1 | MK0251YGKB56HA | MK7OAA10 | 1.818 TB | -| 2 | MK0251YGKB4N2A | MK7OAA10 | 1.818 TB | -| 3 | MK0251YGKB58LA | MK7OAA10 | 1.818 TB | -| 4 | MJ1311YNG6XEVA | MEAOA5C0 | 2.728 TB | - -2021.08.19 LUN0 drive MK0171YFK3TVGA removed - -## vm3.sea.rg.net Hardware - - **[SuperMicro SuperServer 6019U-TRT](https://www.supermicro.com/products/system/1U/6019/SYS-6019U-TRT.cfm)** - -- [X10DRW-iT Motherboard](https://www.supermicro.com/products/motherboard/Xeon/C600/X10DRW-IT.cfm) -- [Two Intel Ten Core 2.4Ghz Xeon 25MB cache 8.0GT/s QPI (90W) (E5-2640v4)](http://ark.intel.com/products/92984/Intel-Xeon-Processor-E5-2640-v4-25M-Cache-2_40-GHz) -- 128G RAM - 8x16GB DDR4 2400Mhz 19200 ECC/REG -- [Four HGST 6TB Enterprise SATA3 6Gb/s 7200RPM 128MB](https://www.hgst.com/products/hard-drives/ultrastar-7k6000) - -### vm3.sea drives, we guess numbered left to right - -From `for i in a b c d; do smartctl -a /dev/sd$i | egrep 'Model|Serial|Capacity'; done` - -| Bay | Model | Serial | Capacity | Installed | -| ---- | -------------------- | -------------- | -------- | ---------- | -| 0 | HGST HUS726060ALE610 | K1J48AGD | 6TB | 2017.08.17 | -| 1 | HGST HUS726060ALE610 | K1J2PTND | 6TB | 2017.08.17 | bad -| 2 | HGST HUS726060ALE610 | K8J6HV2N | 6TB | 2022.09.15 | -| 3 | HGST HUS726060ALE610 | K1J46RHD | 6TB | 2017.08.17 | - -replaced: -| 2 | HGST HUS726060ALA640 | AR11001EV17LLB | 6TB | 2022.09.15 | -``` - -for i in b c d e; do echo $i; smartctl -a /dev/sd$i | egrep '(^Serial|Extended)'; done - -## psg.com - -[SUPERMICRO AS-1012G-MTF 1U Rackmount](http://www.supermicro.com/Aplus/system/1U/1012/AS-1012G-MTF.cfm) [H8SGL-F mobo](http://www.supermicro.com/Aplus/motherboard/Opteron6000/SR56x0/H8SGL-F.cfm) - -From `for i in 0 1 2 3 4; do smartctl -a /dev/ada$i | egrep 'Model|Serial|Capacity'; done` - -| LUN | Model | Serial | Size | -| ---- | ---------------------- | --------------- | ---- | -| 0 | WDC WD2000F9YZ-09N20L0 | WD-WCC1P0469969 | 2TB | -| 1 | WDC WD2005FBYZ-01YCBB1 | WD-WMC6N0F1F8SD | 2TB | - -WDC WD2000F9YZ-09N20L0 WD-WCC1P0648270 removed from ata1 2017.04.09 - -WD-WCC1P0654846 replaced on 2017.03.04 - -## vm4.sea.rg.net Hardware - -- Dell Poweredge R630 Server 2xE5-2640V4 10-core 2.4GHz, 256GB RAM, H730 -- Service tag: 6TL7MN2 -- Express Service Code 14849840990 -- [How to configure the DELL PERC H700/H710/H730/H730P RAID controller](https://www.scaleway.com/en/docs/dedibox/hardware/how-to/configure-dell-perc-h700/) - - -## raid0.sea.rg.net - -- [5018R-WR Chassis + MoBo](https://www.supermicro.com/products/system/1u/5018/sys-5018r-wr.cfm) -- [X10SRW-F Motherboard](https://www.supermicro.com/products/motherboard/Xeon/C600/X10SRW-F.cfm) -- [Intel Xeon® Processor E5-2609 v4](https://ark.intel.com/products/92990/Intel-Xeon-Processor-E5-2609-v4-20M-Cache-1-70-GHz-) -- Samsung DDR4 2133MHzCL15 16GB RegECC 2Rx4 (PC4 2133) Internal Memory M393A2G40DB0-CPB -- FreeBSD USB key left in USB port - - -### raid0.sea.rg.net Drive Bays - - From `for i in {0..3}; do smartctl -a /dev/ada$i | egrep 'Model|Serial|Capacity'; done` - -| LUN | Model | Serial | Capacity | Date | -| ---- | -------------------- | --------------- | -------- | ---------- | -| 0 | WDC WD60EFRX-68L0BN1 | WD-WX41DA5F88N9 | 6tb | 2018.12.09 | -| 1 | WDC WD60EFRX-68L0BN1 | WD-WX11D363T2Y5 | 6tb | 2018.12.09 | -| 2 | WDC WD60EFRX-68L0BN1 | WD-WX11D3678XTL | 6tb | 2018.12.09 | -| 3 | WDC WD60EFRX-68L0BN1 | WD-WX41D75LN9KC | 6tb | 2018.12.09 | - -## rip.psg.com - -[PDSMU with a Xeon and 4GB RAM](http://www.supermicro.com/products/motherboard/Xeon3000/3010/PDSMU.cfm) - -| LUN | Serial | Model | Size | -| ---- | --------------- | ------------------------------- | ---- | -| 0 | 9QE7MXMC | ST3250820NS | 250G | -| 1 | WD-WMC5C0D5MXU1 | WDC WD2000F9YZ-09N20L1 01.01A02 | 2TB | -| 2 | 9QE7MY84 | ST3250820NS | 250G | -| 3 | WD-WMC5C0E2C2L0 | WDC WD2000F9YZ-09N20L1 01.01A02 | 2TB | - -## Switches - -| name | mfr | model | ip sddress | -| -------------- | ----- | -------------------- | ------------ | -| sw0.sea.rg.net | Cisco | WS-C3750G-48PS | 147.28.0.253 | -| sw3.sea.rg.net | Cisco | Nexus3064 48x10GE +4 | 147.28.0.239 | -| sw4.sea.rg.net | Cisco | Nexus3064 48x10GE +4 | 147.28.0.238 | - -### Remoived - -| sw1.sea.rg.net | SMC | SMC8024L2 | 147.28.0.252 | -| -------------- | ----- | -------------- | ------------ | -| sw2.sea.rg.net | Cisco | WS-C3750G-24PS | 147.28.0.246 | - -## Miscelaneous Data - -### Spare Drives - -| | | | | -| ---------------- | ------------ | -------- | ---- | -| spares in westin | | | | -| | | | | -| HGST | H3D30003254S | YNG1E3ZC | 3TB | -| Seagate | ST31000528AS | 6VPCVN1Y | 1TB | -| Seagate | ST3750640A8 | 3QD06D5B | 750G | -| HGST | 118032816 | YFJLBZ5A | 2TB | -| | | | | - -### r1.sea gigether pic left to right - -| | | -| ------ | --------- | -| LAN | copper | -| unused | copper | -| six | copper | -| unused | fiber sfp | -| | | - - -``` -RGnet, LLC. -c/o Lunavi -2001 6th Avenue, Suite 2402 -Seattle, WA 98121 -Lunavi Support -206 777 9988 -24x7@ccom.net 206-854-3444 and 206-353-5558 - -RGnet rack - Suite 1809 - Cabinet C2 - -GreenHouse tie-down to Verio Backbone - Rack 204 Panel 9 Port A6 - r03.sttlwa01.us.bb so-1/1/0 - -NTT -USID 278679 -r05.sttlwa01.us.bb Gi100/0/0/15 -WAN IPs on your side: -165.254.106.18/30 -2001:418:0:5000::12/126 - -SIX 1G to USC -RGnet.SW3.SEA eth1/46 -RGnet.1809.CAB.C02.P1.1/2 -GHD.1809.CAB.D04.P1.M3 -GHD.19FMMR.RR.405.3.M3 -SIX.19FMMR.RR.506.7.D3 - -SIX 1G to r1 -RGnet.Juniper.Ge-0/0/1 -RGnet.1809.CAB.C02.P1.3/4 -GHD.1809.CAB.D04.P1.M4 -GHD.19FMMR.RR.405.3.M4 -SIX.19FMMR.RR.506.7.E3 - -SIX 10G to Arrcus r2.sea.rg.net -RGnet. r2.sea.rg.net.Ge-0/0/1 -RGnet.1809.CAB.C02.P1.5/6 -GHD.1809.CAB.D04.P2.F4 -GHD.19FMMR.RR.1001.3.F4 -SIX.19FMMR.RR.901.9.A4 - -SprintLink 1G to r1 -RGnet.Juniper.Ge-0/0/2 -RGnet.1809.CAB.C02.P1.7/8 -GHD.1809.CAB.D04.P1.M5 -GHD.19FMMR.RR.405.3.M5 -Sprint.19FMMR.RR.604.5.A5 (9/10) -``` - -``` -Westin NTT/Verio 100baseFX -PSG-STTLWA01-FE-VDR001 (199.238.113.9) -r05.sttlwa01.us.bb.gin.ntt.net. -1000 LX -Westin NTT/Verio OC3 -PSG-STTLWA01-OC3-VDR001 (129.250.11.41) -r02.sttlwa01.us.bb.gin.ntt.net -SM IR -``` - -## Westin Rack Physical and Wiring (INOP) -Physical Hosts and Wiring - -| hostname | switch | ipmi | oob | oobname | pwr | rack | Model | -| :---------------------------- | ----------- | ----- | ---- | ------- | --------- | ----- | ----------------------------------------------------- | -| pwr1.sea.rg.net | s0.16 | | | | 2.x? | 43 | | -| sw4.sea.rg.net | s3.47 | | 0.08 | sw4 | 1.1 | 41 | Cisco Nexus-3064 | -| rcuss0.rg.net | s0.23 | N/A | 0.01 | rcuss0 | 1.2 | 40 | Redstone | -| vm3.sea.rg.net | s4.20/s4.22 | s4.18 | ???? | vm3 | 0.2 | 39 | SuperMicro SuperServer 6019U-TRT | -| r2.sea.rg.net | s0.14 s4.36 | | 0.09 | r2 | 1.7 | 37-38 | Arrcus xxx q2c aka sixa.rg.net | -| vm4.sea.rg.net | s4.45/s4.46 | s3.5 | xxxx | xxx | 1.3 | 36 | Dell 630 -| vm2.sea.rg.net | s0.41/s0.31 | s0.41 | 0.05 | vm2 | 2.7 2.1 | 34-35 | SuperMicro AS-2022G-URF 2RU Chassis | -| psg.com | s0.13 | s0.19 | 0.02 | psg | 1.5 | 33 | (see below) | -| seattle01.mux.peering.usc.edu | s0.11 s0.38 | 0.20 | | | | 31 | Supermicro Ethan Katz-Bassett | -| sw3.sea.rg.net | s0.47 | | 0.07 | sw3 | 0.7 | 27 | Cisco Nexus-3064 | -| sw0.sea.rg.net | s3.48 | | 0.06 | sw0 | 0.4 | 26 | Cisco WS-C3750G-POE-48 | -| pwr2.sea.rg.net | s0.10 | | | | | 21 | | -| atlas0.sea.rg.net | s0.25 | | | | | 20.5 | | -| raid0.sea.rg.net | s0.27 | s0.03 | ???? | raid0 | 0.6 | 19 | SuperMicro 5018R-WR | -| o0.sea.rg.net | s0.06 | | | | 2.4 | 18 | Cyclades ACS-48 | -| vm1.sea.rg.net | s0.34/s0.30 | s0.33 | | vm1 | 0.2 | 16-17 | (see below) | -| vm0.sea.rg.net | s0.26/s0.29 | s0.39 | 0.03 | vm0 | 2.5/2.7 | 15 | Supermicro - w/ X7DWU | -| pwr3.sea.rg.net | s0.18 | | | | x.3 | 13 | | -| pwr0.sea.rg.net | s0.12 | | | | | 11 | | -| r0.sea.rg.net | s0.35/46 | | 0.11 | r0 | 0.8 & 3.7 | 7 | Cisco ASR1001 commissioned 2018.02.02 | -| r1.sea.rg.net | s0.17 | | 0.10 | r1 | 2.1 & 3.1 | 5-6 | Juniper M7i | - -### Removed -Removed from Rack - -| hostname | switch | ipmi | oob | oobname | pwr | rack | Model | -| :-------------- | ----------- | ---- | ----- | ------- | --------- | ----- | ------------------------------------- | -| rip.psg.com | s4.32 0.04 | rip | 1.04 | 36 | NOW VIRT ON VM4 Supermicro 5015M-NTRB w/ Super PDSMU | -| o1.sea.rg.net | s0.15 | | 0.04 | o1 | 2.4 | 24 | Cisco 2511 | -| dum0.sea.rg.net | s2.23 s2.24 | | 1.10 | dum0 | 1.1/1.2 | 42 | Supermicro - w/ PDSMi/PDSMA | -| o0.sea.rg.net | s0.05| 1.13 | o0 | 2.6 | 10 | Cisco 2511 | -| work1.psg.com | s1.11 | | 1.11 | work0 | 3.7 | 39 | decommissioned 2015.07.20 | -| bgp.nu | s0.07/17 | | | | | 37-38 | Paul Southworth | -| sw2.sea.rg.net | s0.48 | | 1.02 | sw2 | 0.7 | 27 | Cisco WS-C3750G-POE | -| sw1.sea.rg.net | s0.01 | | 1.07 | sw1 | ?? | 25 | SMC SMC8024L2 | -| r2.sea.rg.net | s0.14 s2.14 | | 0.09? | r2 | 2.8 | 7 | Cisco 1001 | -| r0.sea.rg.net | s0.03 | | 0.01 | r0 | 0.1 & 3.4 | 2-4 | Cisco 7206g2 decommisioned 2018.02.02 | - - -FastEthernet5/6 is up, line protocol is up (connected) - -Hardware is C6k 100Mb 802.3, address is 00d0.0135.840a (bia 00d0.0135.840a) Description: AX: PSG - local wire - -Westin OC3c sprint facility # 10038527 - -SprintLink noc 800-232-6895 \ - - -FiberCloud tie-down to Sprint in MMR - Rack 303 Panel 1 Port L2 Single Mode - -## Router Topology - -[![200511.westin.jpg](../pics/200511.westin.jpg)] - - -## New Switching - -[![180802.arrcus-sea.jpg](../pics/180802.arrcus-sea.jpg)] - ---- - -2023.04.27