replace drive 0 on vm0
This commit is contained in:
parent
6b45deafdb
commit
3c46cf784a
1 changed files with 15 additions and 17 deletions
|
|
@ -186,42 +186,40 @@ usbeacon2.iibex.auckland.ac.nz vm0.iad.rg.net vm2.iad.rg.net 36.0G 1.0G
|
|||
|
||||
### vm0.iad.rg.net Disk Configuration
|
||||
```
|
||||
vm0.iad.rg.net:/root# tw_cli info
|
||||
vm0.iad.rg.net:/home/randy> sudo tw_cli info
|
||||
|
||||
Ctl Model (V)Ports Drives Units NotOpt RRate VRate BBU
|
||||
------------------------------------------------------------------------
|
||||
c0 9750-4i 4 4 1 0 1 1 -
|
||||
c0 9750-4i 4 4 1 1 1 1 -
|
||||
|
||||
vm0.iad.rg.net:/root# tw_cli info c0
|
||||
vm0.iad.rg.net:/home/randy> sudo tw_cli info c0
|
||||
|
||||
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
|
||||
------------------------------------------------------------------------------
|
||||
u0 RAID-5 OK - - 256K 8381.87 RiW ON
|
||||
u0 RAID-5 REBUILDING 12% - 256K 8381.87 RiW ON
|
||||
|
||||
VPort Status Unit Size Type Phy Encl-Slot Model
|
||||
------------------------------------------------------------------------------
|
||||
p0 OK u0 3.63 TB SATA 0 - WDC WD4002FYYZ-01B7
|
||||
p1 OK u0 3.63 TB SATA 1 - WD4003FRYZ-01F0DB0
|
||||
p0 DEGRADED u0 3.63 TB SATA 0 - WDC WD4003FRYZ-01F0
|
||||
p1 OK u0 3.63 TB SATA 1 - WDC WD4003FRYZ-01F0
|
||||
p2 OK u0 2.73 TB SATA 2 - WDC WD3000FYYZ-01UL
|
||||
p3 OK u0 2.73 TB SATA 3 - HITACHI HUA723030AL
|
||||
```
|
||||
|
||||
### vm0.iad.rg.net Disk Drive Serial Numbers
|
||||
|
||||
From `smartctl --all -s on -T verypermissive --device=3ware,$i /dev/twl0`<br>
|
||||
`smartctl --all --device=3ware,$i /dev/twl0`
|
||||
From `sudo smartctl -a -d 3ware,$i /dev/twl0`
|
||||
|
||||
| Unit | Model | Serial |
|
||||
| ---- | ----------------------- | --------------- |
|
||||
| 0 | WD4002FYYZ-01B7CB1 | K7G9TG6L | getting errors
|
||||
| 1 | WD4003FRYZ-01F0DB0 | V1JVGGHG |
|
||||
| 2 | WD3000FYYZ-01UL1B0 | WD-WCC130095709 |
|
||||
| 3 | HITACHI HUA723030ALA640 | YVHPV0LA |
|
||||
| Unit | Model | Serial | |
|
||||
| ---- | ----------------------- | --------------- | -------------------- |
|
||||
| 0 | WD4003FRYZ-01F0DB0 | VBHVEUTF | new as of 2023.05.17 |
|
||||
| 1 | WD4003FRYZ-01F0DB0 | V1JVGGHG | |
|
||||
| 2 | WD3000FYYZ-01UL1B0 | WD-WCC130095709 | |
|
||||
| 3 | HITACHI HUA723030ALA640 | YVHPV0LA | |
|
||||
|
||||
* 2023.05.17 replaced p0 K7G9TG6L with
|
||||
* 2022.05.18 replaced p1 WDC WD3000FYYZ-01UL serial WD-WCC130121922
|
||||
|
||||
there is a spare 4TB drive in cardboard atop the cisco
|
||||
|
||||
## vm1.iad.rg.net Hardware
|
||||
|
||||
**[SuperMicro AS-1022G-URF 2RU Chassis](http://www.supermicro.com/Aplus/system/1U/1022/AS-1022G-URF.cfm)**
|
||||
|
|
@ -300,4 +298,4 @@ You will face RPC> prompt. Type
|
|||
|
||||
---
|
||||
|
||||
2022.10.28
|
||||
2023.05.17
|
||||
Loading…