From 360b9a4f6840e26e8a99580f2fdad4e51837a422 Mon Sep 17 00:00:00 2001 From: Randy Bush Date: Sat, 19 Oct 2024 19:56:33 -0700 Subject: [PATCH] better listing of VMs --- pages/DallasPoP.md | 1036 ++++++++++++++++++++++---------------------- 1 file changed, 519 insertions(+), 517 deletions(-) diff --git a/pages/DallasPoP.md b/pages/DallasPoP.md index b060472..cb26183 100644 --- a/pages/DallasPoP.md +++ b/pages/DallasPoP.md @@ -1,517 +1,519 @@ -# Dallas Google PoP - -## New Google POP - -``` -Site DFW 28 -Cage 4000.40 -1950 N Stemmons Freeway -Suite 4000 -Dallas, TX 75207 - -Racks 4-11 4-12 - RGnet in 4-12 - IETF/Infra in 4-11 - -Shipping Address: - Google - chris morrow - c/o: Infomart Suite 4000 - 1950 N Stemmons Freeway - Dallas, TX 75207 -``` - -## Infra Hardware Inventory -``` -r1 Juniper MX240 -r2 cisco 9001 -sw0 cisco 2960G-48TC-L with fiber to 12406 -sw2 Nexus3064 48x10GE -sw3 Nexus3064 48x10GE -o2 Cyclades® ACS Advanced Console Server -pwr0 Servertech Horizontal Power Strip (8port) Part Number: CW-8H2-C20 -pwr1 Servertech Horizontal Power Strip (8port) Part Number: CW-8H2-C20 -``` - ---- - -## Rack Physical and Wiring - -| hostname | switch | ipmi | oob | oobname | pwr | rack | | -| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ------- | -------------------| -| o2.dfw.rg.net | sw0.35 | | 1.8 | o2 | | | Cyclades® ACS-48 | -| [equnix IX fiber] | 0.46 | | | | | | | -| r1.dfw.rg.net.2/2/0 | 0.07 | | 2.15 | r1 | | 0.13-17 | LAN | -| r1.dfw.rg.net.2/2/1 | 2.03 | | 2.15 | r2 | | 0.13-17 | NTT (VLAN 53) | -| r2.dfw.rg.net-0/0/1/0 | 2.05 | 0.08 | 2.3 | r2 | | 0.18.19 | NTT VLAN 50 | -| r2.dfw.rg.net.0/1/1 | 2.06 | | 2.3 | | | 0.18.19 | LAN | -| sw0.dfw.rg.net | 2.47 | | 2.13 | sw0 | | 0.28 | Cicso 2960 | -| sw2.dfw.rg.net | 0.47 | | 2.02 | sw2 | [^1 ^2] | 0.30 | Cisco 3064 | -| raid0.dfw.rg.net | [^2] | 0.32 | 2.44 | raid0 | 0.5/1.5 | 0.36-38 | | -| vm0.dfw.rg.net | 2.25 2.26(drbd) | 2.20 | 2.5 | vm0.dfw | pwr0b B1-9 pwr0r B1-9 | 0.40 | SuperMicro | -| vm1.dfw.rg.net | 2.27 2.28(drbd) | 2.19 | 2.6 | vm1.dfw | pwr0b B1-10 pwr0r B1-10 | 0.41 | SuperMicro | -| vm2.dfw.rg.net | 2.23 2.24(drbd) | 2.21 | 2.6 | vm2.dfw | pwr0b B1-10 pwr0r B1-10 | 0.42 | Dell R630 | -| atlas.dfw.rg.net | 0.33 | | | | vm1.dfw USB | | | -| | | | | | | | | -| b0.noc.ietf.org | 3.32 | 3.31 | 2.45 | b0 | 0.4/1.4 | 1.26 | | -| sw3.dfw.rg.net | 2.48 | | 2.30 | sw3 | 0.4/1.4 | 1.30 | Cisco 3064 | -| pwr1.red.dfw.rg.net | 0.41 | | 2.9 | pwr1-red | subfl | 26 | | -| pwr1.blue.dfw.rg.net | 0.41 | | 2.10 | pwr1-blue | subfl | 26 | | -| pwr0-blue.dfw.rg.net | 0.42 | | 2.16 | pwr0-blue | subfl | - | | -| pwr0-red.dfw.rg.net | 0.42 | | 2.17 | pwr0-red | subfl | - | | - -## Removed - -| hostname | switch | ipmi | oob | oobname | pwr | rack | | -| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ------- | -------------------| -| dallas01.mux.peering.usc.edu | 0.38 | | 2.46 | usc | 0.7/1.7 | 1.40 | | -| rtcolo.daedalus.com | | xx | 2.45 | b0 | xx | 1.41 | | - -## Cabling - -[^1]: RGnet VM servers' ethers are connected to sw2.dfw as follows: - -| vm | ipmi | e0 | e1 | -| ---- | ------ | ------ | ------ | -| vm0 | sw2-20 | sw2-25 | sw2-26 | -| vm1 | sw2-19 | sw2-27 | sw2-28 | -| vm2 | sw2-21 | sw2-23 | sw2-24 | - -[^2]: raid0.dfw ethers are connected to sw2.dfw as follows: - -| ipmi | e0 | e1 | 10g 0 | 10g 1 | -| ------ | ------ | ------ | ------ | ------ | -| sw0-32 | sw2-16 | sw2-17 | sw2-29 | sw2-30 | - - -## RGnet Cluster / 198.180.152.30 / 198.180.152.7 / 198.180.152.32 - -``` -vm0.dfw.rg.net:/root# ./do-stat -Node DTotal DFree MTotal MNode MFree Pinst Sinst -vm0.dfw.rg.net 3.1T 1.2T 251.8G 216.3G 217.3G 10 8 -vm1.dfw.rg.net 3.1T 1.7T 251.8G 35.9G 234.5G 9 9 -vm2.dfw.rg.net 3.1T 1.7T 251.8G 35.9G 234.5G 9 9 - -Instance Primary_node Secondary_Nodes Disk/0 Memory VCPUs -baleen.rg.net vm1.dfx.rg.net 16.0G 2.0G 1 -ca.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 128.0G 4.0G 1 -cache0.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 32.0G 2.0G 1 -cats.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 32.0G 2.0G 1 -cu0.dfw.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 12.0G 512M 1 -git.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 32.0G 2.0G 1 -icir.dfw.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 400.0G 8.0G 4 -krill.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 16.0G 2.0G 1 -mail.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 32.0G 1.0G 1 -mon0.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 150.0G 16.0G 4 -netsrv.dfw.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 100.0G 1.0G 1 -nms.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 80.0G 2.0G 2 -petunia.hactrn.net vm0.dfx.rg.net vm1.dfx.rg.net 120.0G 6.0G 1 -r3.dfw.rg.net vm0.dfx.rg.net 32.0G 16.0G 4 -ran.psg.com vm0.dfx.rg.net vm1.dfx.rg.net 32.0G 4.0G 1 -routen8or.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 128.0G 2.0G 1 -wireguard.rg.net vm0.dfx.rg.net vm1.dfx.rg.net 10.0G 2.0G 1 -wp.rg.net vm1.dfx.rg.net vm0.dfx.rg.net 64.0G 4.0G 1 -ymbk.com vm1.dfx.rg.net vm0.dfx.rg.net 16.0G 512M 1 -``` - -## Hosts on vm0/1.dfx.rg.net - -| Instance | Primary_node | Secondary_Node | MaxMem | DiskUsage | IP_Address | SysAdmin | -| ------------------- | -------------- | -------------- | ------ | --------- | --------------- | ------------------------------------------ | -| baleen.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 2.0G | 16.0G | 198.180.152.61 | Randy Bush <randy@psg.com> | -| ca.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 4.0G | 128.0G | 198.180.152.6 | Randy Bush <randy@psg.com> | -| cache0.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 2.0G | 32.0G | 198.180.152.33 | Randy Bush <randy@psg.com> | -| cats.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 2.0G | 32G | 198.180.152.58 | Randy Bush <randy@psg.com> | -| cu0.dfw.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 512M | 12.0G | 198.180.152.71 | Steven M Bellovin <smb@cs.columbia.edu> John Koh <koh@…> | -| git.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 2.0G | 34.0G | 198.180.152.8 | Randy Bush <randy@psg.com> | -| icir.dfw.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 1.0G | 32.0G | 198.180.152.57 | Bill Marczak <billmar@gmail.com> | -| krill.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 2.0G | 16.0G | 198.180.152.62 | Randy Bush <randy@psg.com> | -| mail.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 2.0G | 12.0G | 198.180.152.11 | Randy Bush <randy@psg.com> | -| mon0.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 16G | 150.1G | 198.180.152.62 | Randy Bush <randy@psg.com> | -| netsrv.dfw.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 1.0G | 100G | 198.180.152.15 | Randy Bush <randy@psg.com> | -| nms.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 2.0G | 20G | 198.180.152.9 | Randy Bush <randy@psg.com> | -| petunia.hactrn.net | vm0.dfw.rg,net | vm1.dfw.rg.net | 6G | 120G | 198.180.152.200 | Rob Austein <sra@hactrn.net> | -| ran.psg.vom | vm0.dfw.rg.net | vm1.dfw.rg.net | 4.0G | 32.0G | 198.180.152.18 | Randy Bush <randy@psg.com> | -| routen8or.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 4.0G | 16.0G | 198.180.152.63 | Randy Bush <randy@psg.com> | -| wireguard.rg.net | vm0.dfw.rg.net | vm1.dfw.rg.net | 4G | 64G | 198.180.152.16 | Hans Kuhn <hans@flyingpoodle.com> | -| wp.rg.net | vm1.dfw.rg.net | vm0.dfw.rg.net | 2G | 10G | 198.180.152.56 | Randy Bush <randy@psg.com> | -| ymbk.com | vm1.dfw.rg.net | vm0.dfw.rg.net | 512M | 16.1G | 198.180.152.10 | Randy Bush <randy@psg.com> | - - -## vm0.dfx.rg.net vm1.dfx.rg.net -VMs are [Supermicro A+ Server 1114S-WTRT Systems](https://www.supermicro.com/Aplus/system/1U/1114/AS-1114S-WTRT.cfm)
-With [Supermicro H12SSW-NT Motherboards](https://www.supermicro.com/en/products/motherboard/H12SSW-NT)
-With one AMD EPYCTM 7443P Single Socket Processor 24-Core 2.85GHz
-With 256G of RAM each
-And 2 Samsung 250GB 970 EVO+ Series - M.2 NVMe PCIe (<1DWPD) (MZ-V7S250B)
-And 8 Samsung 960GB 883 DCT Series - 2.5" SSD SATA 6Gb/s (<1DWPD) (MZ-7LH960NE)
-Serial Numbers: iX1210A-IXN S/N's A1-86827 and A1-86828
- -### vm[0-1].dfx.rg.net Disk Drives - -``` -vm0.dfx.rg.net:/home/randy# for i in a b c d e f g h; do echo -n "sd$i "; smartctl -a /dev/sd$i | egrep "Serial|Model"; done -sda Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316039 -sdb Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R107119 -sdc Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316036 -sdd Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316032 -sde Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R303811 -sdf Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316042 -sdg Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R107124 -sdh Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316040 - -vm1.dfx.rg.net:/home/randy# for i in a b c d e f g h; do echo -n "sd$i "; smartctl -a /dev/sd$i | egrep "Serial|Model"; done -sda Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316035 -sdb Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R303827 -sdc Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316034 -sdd Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R303829 -sde Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R303777 -sdf Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R303803 -sdg Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R303764 -sdh Device Model: SAMSUNG MZ7LH960HAJR-00005 -Serial Number: S45NNA0R316031 -``` - -## vm2.dfw.rg.net -Dell 630
-Service tag : 6JGVQD2
-2 x E5-2670v3 2.30GHz 12-Core each
-256G RAM
-2x10G Ether, copper ok, or sfp -H730 RAID
- -## raid0.dfw.rg.net - -Dell R530
-Service Tag: HQWPW52
-PERC H730P RAID Controller, 2G B NV Cache, Mini card
-2 x 4TB in md0 RAID1 as opsys
-5 x 16TB in zfs
-[System Configuration Page](https://www.dell.com/support/home/en-us/product-support/servicetag/0-V1RMSUVWMzFWOUdxdk5Va1doY2oyQT090/overview) - -### Drive Bays - -| | | | | -| ----- | ----- | ----- | ----- | -| Bay 0 | Bay 2 | Bay 4 | Bay 6 | -| Bay 1 | Bay 3 | Bay 5 | Bay 7 | - -Cable to Bay 5 may be bad 2023.07.16 - -### raid0 Drives - -`smartctl -a -d megaraid,[0-7] /dev/bus/0`
-Look for smart scan errors with `for i in 0 1 2 3 4 5 6 7; do echo -n "$i "; smartctl -a -d megaraid,$i /dev/bus/0 | grep 'Completed with'; echo; done` - -| | | | | | -| --- | --------------- | -------------------- | -------------------- | ----------- | -| Bay | Manufacturer | Model | Serial ------------ | Installed | -| 0 | Seagate | ST4000NM0025 | ZC1BBMHX0000C943K87N | 2024.07.28 | -| 1 | Seagate | ST4000NM0005 | Z4C056KT | 2022.06.06 | -| 2 | Western Digital | WD161KRYZ-01AGBB0 | 2PH9PMWT | 2022.06.06 | -| 3 | Western Digital | WD161KRYZ-01AGBB0 | 2PHA0RMT | 2022.06.06 | -| 4 | Western Digital | WD161KRYZ-01AGBB0 | 2PH9NJNT | 2022.06.06 | -| 5 | Western Digital | WD161KRYZ-01AGBBO | 2CH669AP | 2023.08.22 | -| 6 | Seagate | ST16000NM000J-2TW103 | ZR706BX0 | 2022.06.06 | - - -| 0 | Seagate | ST4000NM0005 | Z4C056TC | 2022.06.06 removed 2024.07.17 | -| 5 | Western Digital | WD161KRYZ-01AGBB0 | 2PH69HJJ | removed 2023.07.17 | - - -``` -raid0.dfw.rg.net:/home/randy# for i in 0 1 2 3 4 5 6 7; do echo -n "$i "; smartctl -a -d megaraid,$i /dev/bus/0 | grep 'Serial'; echo; done -0 Serial number: Z4C056TC -1 Serial number: Z4C056KT -2 Serial Number: 2PH9PMWT -3 Serial Number: 2PHA0RMT -4 Serial Number: 2PH9NJNT -5 -6 Serial Number: ZR706BX0 -7 Serial Number: 2PH69HJJ -``` - --------- - -## Disgusting Details -``` -Power - SO1-A:5C2.2-62/64 - SO2-A:5C2.2-66/68 - SO1-B:5D2.2-62/64 - SO2-B:5D2.2-66/68 - C-Side is Blue and that = "A" feed - D-Side is Yellow and that = "B" feed - [ SO2-B:5D2.2-66/68 will not be used ] - -The demarc for the xconnects is as follows: - pp01.dfw06 - 137-138 M3 Future - 139-140 M4 Future - 141-142 M5 Equinix IX Cable ID #20466027 Terminated on CP:0104:1068601 ports 3/4 - 143-144 M6 NTT/Verio r08.dllstx09.us.bb g0/6/0/29 - -Rge Equinix order info for the exchange fiber: -Ordering contact- Chris Morrow and/or CSM- Shazyra Irizarry -Technical contact – Randy Bush -IBX- DA1 -Order: 1-97362053795 -WOA- 3-97445043133 (IX Port Install) -WOA- 3-97448754941 (NCC Cable install) -Serial # 20466027 ; terminated on CP:0104:1068601 ports 3/4 - ---- - -Dallas Equinix Colo, Downstairs - -Google demarc for the riser cable on the Equinix end is Suite 1034 Cage -00372 Cabinet 105 - -NTT/Verio TDI -Cage 220, Cab 101 FP#1, Port NA, SMF/SC. -r08.dllstx09.us.bb g0/6/0/29 - -Media: MMF -Connector: SC - ---- ntt circuit --- - -EQUINIX INC. - Cross Connect Order Complete - 817885.1.1.2 -Completed On: 08-JUN-2009 -IBX: DA1 -Type of Order: Cross Connect -Cage: DA1::00080:EQUINIX.COM -Cabinet Number: 0101 -A-Side Patch Panel/Module/Port: PP:0105:2288||1 -Z-Side Customer and Cage Number: YOUTUBE, LLC - DA1::00372:YOUTUBE -Z-Side Cabinet Number: 0105 -Carrier Circuit ID(if applicable): EQUINIX SANDBOX -Z-Side Patch Panel/Module/Port: VP:0105:69862||143 -Cable ID: 1234912 - -EQUINIX INC. - Cross Connect Order Complete - 817885.2.1.2 -Completed On: 05-JUN-2009 -IBX: DA1 -Type of Order: Cross Connect -Cage: DA1::00080:EQUINIX.COM -Cabinet Number: 0101 -A-Side Patch Panel/Module/Port: PP:0105:74459||3 -Z-Side Customer and Cage Number: NTT AMERICA, INC. - DA1::00220:NTT AMERICA, INC. (Verio) -Z-Side Cabinet Number: 0101 -Carrier Circuit ID(if applicable): EQUINIX SANDBOX -Z-Side Patch Panel/Module/Port: PP:0101:2375||15 -Cable ID: 1234913 - -For both crossconnects, even though the "Cabinet Number" field shows -"0101", the actual Equinix A-Side cab is "0105" as listed in the panel -info. And to reduce cabling and points of failure, the IBX site -technicians said that they would be connecting both crossconnects -directly into each other rather than with an intermediate patch cable. - ---- equinix exchange --- - -csw7.da1, gig 0/35, Sandbox/RGNet, IX, circuit id 1236454 -``` - -## Routers - -[![120131.dallas-routers.jpg](../pics/120131.dallas-routers.jpg)] - -## Tapping BGP Feeds - -[![110617.dfw-data-tap.jpg](../pics/110617.dfw-data-tap.jpg)] - - -## Old Google PoP - -We were in Google POP in Via West - -``` -Viawest/Dataside -1950 Stemmons Freeway, Suite 2033 -Dallas TX 75027 -+1-214-231-0162 -Mark for "inside delivery" - -Google PoP DFW06 -Rack Location: 6.3 -Rack: ESW E-00589-01, Black Caster and Mounting Rails, No Door, 7Ft. -``` - ---- - -## Devices Removed - -| hostname | switch | ipmi | oob | oobname | pwr | rack | | -| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ----- | ------------------------------------- | -| r0.dfw.rg.net-rp0 | 0.45 | | 0.01 | r00 | subfl | 03-13 | | -| r0.dfw.rg.net-rp0mgt | 0.33 | | | | | 03-13 | | -| r0.dfw.rg.net-rp1 | 0.?? | | 0.02 | r01 | | 03-13 | | -| o1.dfw.rg.net | 0.40 | | 0.aux | | 1.1 | 0.22-23 | | -| r0.dfw.rg.net-rp1mgt | 0.34 | | | | | 03-13 | | -| [r0.2/0/4 LAN] | 0.04 | | | | | 03-13 | | -| [r0.2/0/5 ntt fiber] | 0.05 | | | | | 03-13 | | -| [r0.2/0/6 spare] | 0.06 | | | | | 03-13 | | -| [r0.2/0/7 equinix ix] | 0.15 | | | | | 03-13 | | -| sw1.dfw.rg.net | | | 0.13 | sw1 | [^1] | 0.35 | | - -[^2]: PTSS/B is connected to power 0.2/1.2 and controls both sw0 and sw1 - - - -## DEAD raid0.dfw.rg.net - -[Mobo Supermicro X7SB4/E](https://www.supermicro.com/products/motherboard/Xeon3000/3210/X7SB4.cfm) [IPMI AOC-IPMI20-E](http://www.supermicro.com/products/accessories/addon/AOC-IPMI20-E.cfm) - -### raid0 disk drive physical order markings on drive carriers - -| | | | | -| ---- | ---- | ---- | ---- | -| 00 | 10 | 20 | 30 | -| 01 | 11 | 21 | 31 | -| 02 | 12 | 22 | 32 | -| 03 | 13 | 23 | 33 | - - -``` -for i in 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16; do - echo -n "1/$i "; - smartctl -i -d hpt,1/$i /dev/hptrr | grep ^Serial; - done -``` -1/1 Serial Number: WD-WMAZA9378538 -1/2 Serial Number: V1KVXSXG -1/3 Serial Number: YGGU1YTA -1/4 Serial Number: WD-WMAZA9520754 -1/5 Serial Number: WD-WCAVY0114154 -1/6 Serial Number: WD-WMC5C0D9L6HV -1/7 Serial Number: WD-WCC6N5UY8H5P -1/8 Serial Number: WD-WCC300759632 -1/9 Serial Number: WD-WCC6N6DDJ7DT -1/10 Serial Number: WD-WCC6N6VTE2NF -1/11 Serial Number: WD-WMC5C0D8Z7FV -1/12 Serial Number: WD-WMC6N0J6S9AV -1/13 Serial Number: WD-WCC4MLULA4S4 -1/14 Serial Number: WD-WMC6N0F8FU0U -1/15 Serial Number: WD-WCAVY0090692 -1/16 Serial Number: WD-WCC6N5CLHYSS - -| Bay | ID | Drive | Name | Serial Number | -| ---- | ---- | ----- | --------- | --------------- | -| 20 | 1/1 | da0 | JBOD-1-1 | WD-WMAZA9378538 | -| 21 | 1/2 | da1 | JBOD-1-2 | V1KVXSXG | -| 22 | 1/3 | da2 | JBOD-1-3 | WD-WCC300755734 | -| 23 | 1/4 | da3 | JBOD-1-4 | WD-WMAZA9520754 | -| 00 | 1/5 | da4 | JBOD-1-5 | WD-WCAVY0114154 | -| 01 | 1/6 | da5 | JBOD-1-6 | WD-WMC5C0D9L6HV | -| 02 | 1/7 | da6 | JBOD-1-7 | WD-WCC6N5UY8H5P | -| 03 | 1/8 | da7 | JBOD-1-8 | WD-WCC300759632 | -| 30 | 1/9 | da8 | JBOD-1-9 | WD-WCC6N6DDJ7DT | -| 31 | 1/10 | da9 | JBOD-1/10 | WD-WCC6N6VTE2NF | -| 32 | 1/11 | da10 | JBOD-1/11 | WD-WMC5C0D8Z7FV | -| 33 | 1/12 | da11 | JBOD-1/12 | WD-WMC6N0J6S9AV | -| 10 | 1/13 | da12 | JBOD-1/13 | WD-WCC4MLULA4S4 | -| 11 | 1/14 | da13 | JBOD-1/14 | WD-WMC6N0F8FU0U | -| 12 | 1/15 | da14 | JBOD-1/15 | WD-WCAVY0090692 | -| 13 | 1/16 | da15 | JBOD-1/16 | WD-WCC6N5CLHYSS | - -* da1 MK0171YFKMA4AG replaced 2022.05.08 -* da12 MK0171YFKMA59G replaced 2022.04.12 -* da8 WD-WCAVY0111166 replaced 2021.11.22 -* da10 WD-WCAVY0127426 replaced 2016.09.15 -* da1 S2F06GX5 replaced 2016.01.2? -* da2 WD-WCAVY0112831 replaced 2014.05.12 -* da5 WD-WCAVY0107135 replaced 2017.03.25 -* da13 W1E0B4NJ replaced 2017.06.xx -* da6 WD-WCAVY0127865 replaced 2018.01.07 -* da6 WD-WMC6N0H8K48M replaced 2021.01.16 -* da9 WD-WCAVY0117958 replaced 2021.03.15 -* da15 WD-WCC4M5VJ4UK3 replaced 2021.06.18 -* da9 WD-WMAY04440674 replaced 2021.08.27 - -## Decommissioned - -dfw0 1ru compute server SuperMicro SYS-6015W-NTRB w/ X7DWU
-dfw1 3ru big raid server SuperMicro CSE-836TQ-R800B w/ X7SBE
-dfw2 2ru Junosphere virtualization server
- -## DEAD dfw0.psg.com - -dfw0 drives `for i in 4 5 6 7; do echo /dev/ad$i; smartctl -a /dev/ad$i | egrep 'Model|Serial'; done` - -| | | | | -| ---- | ------------------ | ------------ | ---- | -| Bay | Model | Serial | | -| | | | | -| ada0 | ST31000340NS | 9QJ3Q29E | 1TB | -| ada1 | WD20EADS-00R6B0 | WCAVY0388932 | 2TB | -| ada2 | WD2005FBYZ-01YCBB1 | WMC6N0F2KZU6 | 2TB | -| ada3 | ST31000340NS | 9QJ3M5N4 | 1TB | -| | | | | - -dfw0 disk drive physical order - -| ada4 | ada6 | ada5 | ada7 | -| ---- | ---- | ---- | ---- | -| ada0 | ada2 | ada1 | ada3 | - -logical drive labels - -| label/disk00 | ada0s3 | -| ------------ | ------ | -| label/disk01 | ada1s3 | -| label/disk02 | ada2s1 | -| label/disk03 | ada3s1 | - -## DEAD nfs0.dfw.rg.net - -### MoBo -* [PDSME+](http://www.supermicro.com/products/motherboard/Xeon3000/3010/PDSME_.cfm) -* [​AOC-SIM1U+ IPMI Card](http://www.supermicro.com/products/accessories/addon/SIM.cfm) - -### DEAD nfs0.dfw.rg.net Disk Drives -``` -for i in 0 1 2 3 4 5 6 7; do tw_cli /c2/p$i show serial; done -``` - -| Port | Model | Serial | Size | Date | -| -------- | ------------------ | --------------- | ---- | ------------------ | -| p0 | ST4000DM000-1F2168 | Z300L98C | 4TB | don't know | -| p1 | WD4000F9YZ-09N20L1 | WD-WCC5D1DS4012 | 4TB | 2019.04.07 | -| p2 | WD60EFRX-68L0BN1 | WD-WX41DA57H7UJ | 6TB | 2018.03.09 | -| p3 | WD4000F9YZ-09N20L1 | WD-WCC5D2KHHYE8 | 4TB | 2016.06.09 | -| p4 | ST4000DM000-1F2168 | Z300KBMM | 4TB | don't know | -| p5 | ST4000DM000-1F2168 | Z300KBQN | 4TB | don't know | -| p6 | ST4000DM000-1F2168 | Z300L8J5 | 4TB | don't know | -| p7 | WD4000F9YZ-09N20L1 | WD-WMC5D0D7V0L9 | 4TB | 2015.12.13 | -| | | | | | -| p1 | ST4000DM000-1F2168 | Z300FKES | 4TB | removed 2019.04.07 | -| p2 | ST4000DM000-1F2168 | Z300L9T3 | 4TB | removed 2018.03.09 | -| incoming | HUS724040ALS640 | PBK4K70X | 4TB | 2015.12.18 | - -### Physical Drive layout - -| | | | | -| ---- | ---- | ---- | ---- | -| 4 | 5 | 6 | 7 | -| 0 | 1 | 2 | 3 | - ---- -2024.10.06 +# Dallas Google PoP + +## New Google POP + +``` +Site DFW 28 +Cage 4000.40 +1950 N Stemmons Freeway +Suite 4000 +Dallas, TX 75207 + +Racks 4-11 4-12 + RGnet in 4-12 + IETF/Infra in 4-11 + +Shipping Address: + Google - chris morrow + c/o: Infomart Suite 4000 + 1950 N Stemmons Freeway + Dallas, TX 75207 +``` + +## Infra Hardware Inventory +``` +r1 Juniper MX240 +r2 cisco 9001 +sw0 cisco 2960G-48TC-L with fiber to 12406 +sw2 Nexus3064 48x10GE +sw3 Nexus3064 48x10GE +o2 Cyclades® ACS Advanced Console Server +pwr0 Servertech Horizontal Power Strip (8port) Part Number: CW-8H2-C20 +pwr1 Servertech Horizontal Power Strip (8port) Part Number: CW-8H2-C20 +``` + +--- + +## Rack Physical and Wiring + +| hostname | switch | ipmi | oob | oobname | pwr | rack | | +| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ------- | -------------------| +| o2.dfw.rg.net | sw0.35 | | 1.8 | o2 | | | Cyclades® ACS-48 | +| [equnix IX fiber] | 0.46 | | | | | | | +| r1.dfw.rg.net.2/2/0 | 0.07 | | 2.15 | r1 | | 0.13-17 | LAN | +| r1.dfw.rg.net.2/2/1 | 2.03 | | 2.15 | r2 | | 0.13-17 | NTT (VLAN 53) | +| r2.dfw.rg.net-0/0/1/0 | 2.05 | 0.08 | 2.3 | r2 | | 0.18.19 | NTT VLAN 50 | +| r2.dfw.rg.net.0/1/1 | 2.06 | | 2.3 | | | 0.18.19 | LAN | +| sw0.dfw.rg.net | 2.47 | | 2.13 | sw0 | | 0.28 | Cicso 2960 | +| sw2.dfw.rg.net | 0.47 | | 2.02 | sw2 | [^1 ^2] | 0.30 | Cisco 3064 | +| raid0.dfw.rg.net | [^2] | 0.32 | 2.44 | raid0 | 0.5/1.5 | 0.36-38 | | +| vm0.dfw.rg.net | 2.25 2.26(drbd) | 2.20 | 2.5 | vm0.dfw | pwr0b B1-9 pwr0r B1-9 | 0.40 | SuperMicro | +| vm1.dfw.rg.net | 2.27 2.28(drbd) | 2.19 | 2.6 | vm1.dfw | pwr0b B1-10 pwr0r B1-10 | 0.41 | SuperMicro | +| vm2.dfw.rg.net | 2.23 2.24(drbd) | 2.21 | 2.6 | vm2.dfw | pwr0b B1-11 pwr0r B1-11 | 0.42 | Dell R630 | +| atlas.dfw.rg.net | 0.33 | | | | vm1.dfw USB | | | +| | | | | | | | | +| b0.noc.ietf.org | 3.32 | 3.31 | 2.45 | b0 | 0.4/1.4 | 1.26 | | +| sw3.dfw.rg.net | 2.48 | | 2.30 | sw3 | 0.4/1.4 | 1.30 | Cisco 3064 | +| pwr1.red.dfw.rg.net | 0.41 | | 2.9 | pwr1-red | subfl | 26 | | +| pwr1.blue.dfw.rg.net | 0.41 | | 2.10 | pwr1-blue | subfl | 26 | | +| pwr0-blue.dfw.rg.net | 0.42 | | 2.16 | pwr0-blue | subfl | - | | +| pwr0-red.dfw.rg.net | 0.42 | | 2.17 | pwr0-red | subfl | - | | + +## Removed + +| hostname | switch | ipmi | oob | oobname | pwr | rack | | +| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ------- | -------------------| +| dallas01.mux.peering.usc.edu | 0.38 | | 2.46 | usc | 0.7/1.7 | 1.40 | | +| rtcolo.daedalus.com | | xx | 2.45 | b0 | xx | 1.41 | | + +## Cabling + +[^1]: RGnet VM servers' ethers are connected to sw2.dfw as follows: + +| vm | ipmi | e0 | e1 | +| ---- | ------ | ------ | ------ | +| vm0 | sw2-20 | sw2-25 | sw2-26 | +| vm1 | sw2-19 | sw2-27 | sw2-28 | +| vm2 | sw2-21 | sw2-23 | sw2-24 | + +[^2]: raid0.dfw ethers are connected to sw2.dfw as follows: + +| ipmi | e0 | e1 | 10g 0 | 10g 1 | +| ------ | ------ | ------ | ------ | ------ | +| sw0-32 | sw2-16 | sw2-17 | sw2-29 | sw2-30 | + + +## RGnet Cluster / 198.180.152.30 / 198.180.152.7 / 198.180.152.32 + +``` +vm0.dfw.rg.net:/root# qm list + VMID NAME STATUS MEM(MB) DISK(GB) PID + 111 cats.rg.net running 2048 32.00 21557 + 112 cu0.dfw.rg.net running 1024 12.00 368895 + 114 mail.rg.net running 2048 32.00 368301 + 115 mon0.rg.net running 4096 150.00 367610 + 117 wp.rg.net running 2048 64.00 369294 + 118 ymbk.com running 1024 16.00 65127 + 119 pfs.dfw.rg.net running 1024 8.00 578419 +vm1.dfw.rg.net:/home/randy> sudo qm list + VMID NAME STATUS MEM(MB) DISK(GB) PID + 102 git.rg.net running 3072 32.00 118589 + 104 netsrv.dfw.rg.net running 2046 100.00 119982 + 107 r3.dfw.rg.net running 4096 32.00 121141 + 110 baleen.rg.net running 2048 16.00 35309 + 113 krill.rg.net running 2048 16.00 34511 + 116 routen8or.rg.net running 2048 128.00 33328 + 120 a1000006.rg.net running 512 8.00 3380241 +vm2.dfw.rg.net:/home/randy> sudo qm list + VMID NAME STATUS MEM(MB) DISK(GB) PID + 100 cache0.rg.net running 3072 32.00 807710 + 101 ca.rg.net running 5120 128.00 806001 + 103 icir.dfw.rg.net running 8192 400.00 423985 + 105 nms.rg.net running 2048 80.00 424708 + 106 petunia.hactrn.net running 6144 120.00 302667 + 108 ran.psg.com running 4096 32.00 321425 + 109 wireguard.rg.net running 2048 10.00 325624 +``` + +## Hosts on vm0/1.dfx.rg.net + +| Instance | MaxMem | DiskUsage | IP_Address | SysAdmin | +| ------------------- | ------ | --------- | --------------- | ------------------------------------------ | +| a1000004.rg.net | 512K | 8G | 198.180.152.33 | Randy Bush | +| baleen.rg.net | 2.0G | 16.0G | 198.180.152.61 | Randy Bush <randy@psg.com> | +| ca.rg.net | 4.0G | 128.0G | 198.180.152.6 | Randy Bush <randy@psg.com> | +| cache0.rg.net | 2.0G | 32.0G | 198.180.152.33 | Randy Bush <randy@psg.com> | +| cats.rg.net | 2.0G | 32G | 198.180.152.58 | Randy Bush <randy@psg.com> | +| cu0.dfw.rg.net | 512M | 12.0G | 198.180.152.71 | Steven M Bellovin <smb@cs.columbia.edu> John Koh <koh@…> | +| git.rg.net | 2.0G | 34.0G | 198.180.152.8 | Randy Bush <randy@psg.com> | +| icir.dfw.rg.net | 1.0G | 32.0G | 198.180.152.57 | Bill Marczak <billmar@gmail.com> | +| krill.rg.net | 2.0G | 16.0G | 198.180.152.62 | Randy Bush <randy@psg.com> | +| mail.rg.net | 2.0G | 12.0G | 198.180.152.11 | Randy Bush <randy@psg.com> | +| mon0.rg.net | 16G | 150.1G | 198.180.152.62 | Randy Bush <randy@psg.com> | +| netsrv.dfw.rg.net | 1.0G | 100G | 198.180.152.15 | Randy Bush <randy@psg.com> | +| nms.rg.net | 2.0G | 20G | 198.180.152.9 | Randy Bush <randy@psg.com> | +| petunia.hactrn.net | 6G | 120G | 198.180.152.200 | Rob Austein <sra@hactrn.net> | +| ran.psg.vom | 4.0G | 32.0G | 198.180.152.18 | Randy Bush <randy@psg.com> | +| routen8or.rg.net | 4.0G | 16.0G | 198.180.152.63 | Randy Bush <randy@psg.com> | +| wireguard.rg.net | 4G | 64G | 198.180.152.16 | Hans Kuhn <hans@flyingpoodle.com> | +| wp.rg.net | 2G | 10G | 198.180.152.56 | Randy Bush <randy@psg.com> | +| ymbk.com | 512M | 16.1G | 198.180.152.10 | Randy Bush <randy@psg.com> | + + +## vm0.dfx.rg.net vm1.dfx.rg.net +VMs are [Supermicro A+ Server 1114S-WTRT Systems](https://www.supermicro.com/Aplus/system/1U/1114/AS-1114S-WTRT.cfm)
+With [Supermicro H12SSW-NT Motherboards](https://www.supermicro.com/en/products/motherboard/H12SSW-NT)
+With one AMD EPYCTM 7443P Single Socket Processor 24-Core 2.85GHz
+With 256G of RAM each
+And 2 Samsung 250GB 970 EVO+ Series - M.2 NVMe PCIe (<1DWPD) (MZ-V7S250B)
+And 8 Samsung 960GB 883 DCT Series - 2.5" SSD SATA 6Gb/s (<1DWPD) (MZ-7LH960NE)
+Serial Numbers: iX1210A-IXN S/N's A1-86827 and A1-86828
+ +### vm[0-1].dfx.rg.net Disk Drives + +``` +vm0.dfx.rg.net:/home/randy# for i in a b c d e f g h; do echo -n "sd$i "; smartctl -a /dev/sd$i | egrep "Serial|Model"; done +sda Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316039 +sdb Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R107119 +sdc Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316036 +sdd Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316032 +sde Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R303811 +sdf Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316042 +sdg Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R107124 +sdh Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316040 + +vm1.dfx.rg.net:/home/randy# for i in a b c d e f g h; do echo -n "sd$i "; smartctl -a /dev/sd$i | egrep "Serial|Model"; done +sda Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316035 +sdb Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R303827 +sdc Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316034 +sdd Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R303829 +sde Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R303777 +sdf Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R303803 +sdg Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R303764 +sdh Device Model: SAMSUNG MZ7LH960HAJR-00005 +Serial Number: S45NNA0R316031 +``` + +## vm2.dfw.rg.net +Dell 630
+Service tag : 6JGVQD2
+2 x E5-2670v3 2.30GHz 12-Core each
+256G RAM
+2x10G Ether, copper ok, or sfp +H730 RAID
+ +## raid0.dfw.rg.net + +Dell R530
+Service Tag: HQWPW52
+PERC H730P RAID Controller, 2G B NV Cache, Mini card
+2 x 4TB in md0 RAID1 as opsys
+5 x 16TB in zfs
+[System Configuration Page](https://www.dell.com/support/home/en-us/product-support/servicetag/0-V1RMSUVWMzFWOUdxdk5Va1doY2oyQT090/overview) + +### Drive Bays + +| | | | | +| ----- | ----- | ----- | ----- | +| Bay 0 | Bay 2 | Bay 4 | Bay 6 | +| Bay 1 | Bay 3 | Bay 5 | Bay 7 | + +Cable to Bay 5 may be bad 2023.07.16 + +### raid0 Drives + +`smartctl -a -d megaraid,[0-7] /dev/bus/0`
+Look for smart scan errors with `for i in 0 1 2 3 4 5 6 7; do echo -n "$i "; smartctl -a -d megaraid,$i /dev/bus/0 | grep 'Completed with'; echo; done` + +| | | | | | +| --- | --------------- | -------------------- | -------------------- | ----------- | +| Bay | Manufacturer | Model | Serial ------------ | Installed | +| 0 | Seagate | ST4000NM0025 | ZC1BBMHX0000C943K87N | 2024.07.28 | +| 1 | Seagate | ST4000NM0005 | Z4C056KT | 2022.06.06 | +| 2 | Western Digital | WD161KRYZ-01AGBB0 | 2PH9PMWT | 2022.06.06 | +| 3 | Western Digital | WD161KRYZ-01AGBB0 | 2PHA0RMT | 2022.06.06 | +| 4 | Western Digital | WD161KRYZ-01AGBB0 | 2PH9NJNT | 2022.06.06 | +| 5 | Western Digital | WD161KRYZ-01AGBBO | 2CH669AP | 2023.08.22 | +| 6 | Seagate | ST16000NM000J-2TW103 | ZR706BX0 | 2022.06.06 | + + +| 0 | Seagate | ST4000NM0005 | Z4C056TC | 2022.06.06 removed 2024.07.17 | +| 5 | Western Digital | WD161KRYZ-01AGBB0 | 2PH69HJJ | removed 2023.07.17 | + + +``` +raid0.dfw.rg.net:/home/randy# for i in 0 1 2 3 4 5 6 7; do echo -n "$i "; smartctl -a -d megaraid,$i /dev/bus/0 | grep 'Serial'; echo; done +0 Serial number: Z4C056TC +1 Serial number: Z4C056KT +2 Serial Number: 2PH9PMWT +3 Serial Number: 2PHA0RMT +4 Serial Number: 2PH9NJNT +5 +6 Serial Number: ZR706BX0 +7 Serial Number: 2PH69HJJ +``` + +-------- + +## Disgusting Details +``` +Power + SO1-A:5C2.2-62/64 + SO2-A:5C2.2-66/68 + SO1-B:5D2.2-62/64 + SO2-B:5D2.2-66/68 + C-Side is Blue and that = "A" feed + D-Side is Yellow and that = "B" feed + [ SO2-B:5D2.2-66/68 will not be used ] + +The demarc for the xconnects is as follows: + pp01.dfw06 + 137-138 M3 Future + 139-140 M4 Future + 141-142 M5 Equinix IX Cable ID #20466027 Terminated on CP:0104:1068601 ports 3/4 + 143-144 M6 NTT/Verio r08.dllstx09.us.bb g0/6/0/29 + +Rge Equinix order info for the exchange fiber: +Ordering contact- Chris Morrow and/or CSM- Shazyra Irizarry +Technical contact – Randy Bush +IBX- DA1 +Order: 1-97362053795 +WOA- 3-97445043133 (IX Port Install) +WOA- 3-97448754941 (NCC Cable install) +Serial # 20466027 ; terminated on CP:0104:1068601 ports 3/4 + +--- + +Dallas Equinix Colo, Downstairs + +Google demarc for the riser cable on the Equinix end is Suite 1034 Cage +00372 Cabinet 105 + +NTT/Verio TDI +Cage 220, Cab 101 FP#1, Port NA, SMF/SC. +r08.dllstx09.us.bb g0/6/0/29 + +Media: MMF +Connector: SC + +--- ntt circuit --- + +EQUINIX INC. - Cross Connect Order Complete - 817885.1.1.2 +Completed On: 08-JUN-2009 +IBX: DA1 +Type of Order: Cross Connect +Cage: DA1::00080:EQUINIX.COM +Cabinet Number: 0101 +A-Side Patch Panel/Module/Port: PP:0105:2288||1 +Z-Side Customer and Cage Number: YOUTUBE, LLC + DA1::00372:YOUTUBE +Z-Side Cabinet Number: 0105 +Carrier Circuit ID(if applicable): EQUINIX SANDBOX +Z-Side Patch Panel/Module/Port: VP:0105:69862||143 +Cable ID: 1234912 + +EQUINIX INC. - Cross Connect Order Complete - 817885.2.1.2 +Completed On: 05-JUN-2009 +IBX: DA1 +Type of Order: Cross Connect +Cage: DA1::00080:EQUINIX.COM +Cabinet Number: 0101 +A-Side Patch Panel/Module/Port: PP:0105:74459||3 +Z-Side Customer and Cage Number: NTT AMERICA, INC. + DA1::00220:NTT AMERICA, INC. (Verio) +Z-Side Cabinet Number: 0101 +Carrier Circuit ID(if applicable): EQUINIX SANDBOX +Z-Side Patch Panel/Module/Port: PP:0101:2375||15 +Cable ID: 1234913 + +For both crossconnects, even though the "Cabinet Number" field shows +"0101", the actual Equinix A-Side cab is "0105" as listed in the panel +info. And to reduce cabling and points of failure, the IBX site +technicians said that they would be connecting both crossconnects +directly into each other rather than with an intermediate patch cable. + +--- equinix exchange --- + +csw7.da1, gig 0/35, Sandbox/RGNet, IX, circuit id 1236454 +``` + +## Routers + +[![120131.dallas-routers.jpg](../pics/120131.dallas-routers.jpg)] + +## Tapping BGP Feeds + +[![110617.dfw-data-tap.jpg](../pics/110617.dfw-data-tap.jpg)] + + +## Old Google PoP + +We were in Google POP in Via West + +``` +Viawest/Dataside +1950 Stemmons Freeway, Suite 2033 +Dallas TX 75027 ++1-214-231-0162 +Mark for "inside delivery" + +Google PoP DFW06 +Rack Location: 6.3 +Rack: ESW E-00589-01, Black Caster and Mounting Rails, No Door, 7Ft. +``` + +--- + +## Devices Removed + +| hostname | switch | ipmi | oob | oobname | pwr | rack | | +| :--------------------------- | ---------------------| ------------ | ------- | ---------- | ---------------------------| ----- | ------------------------------------- | +| r0.dfw.rg.net-rp0 | 0.45 | | 0.01 | r00 | subfl | 03-13 | | +| r0.dfw.rg.net-rp0mgt | 0.33 | | | | | 03-13 | | +| r0.dfw.rg.net-rp1 | 0.?? | | 0.02 | r01 | | 03-13 | | +| o1.dfw.rg.net | 0.40 | | 0.aux | | 1.1 | 0.22-23 | | +| r0.dfw.rg.net-rp1mgt | 0.34 | | | | | 03-13 | | +| [r0.2/0/4 LAN] | 0.04 | | | | | 03-13 | | +| [r0.2/0/5 ntt fiber] | 0.05 | | | | | 03-13 | | +| [r0.2/0/6 spare] | 0.06 | | | | | 03-13 | | +| [r0.2/0/7 equinix ix] | 0.15 | | | | | 03-13 | | +| sw1.dfw.rg.net | | | 0.13 | sw1 | [^1] | 0.35 | | + +[^2]: PTSS/B is connected to power 0.2/1.2 and controls both sw0 and sw1 + + + +## DEAD raid0.dfw.rg.net + +[Mobo Supermicro X7SB4/E](https://www.supermicro.com/products/motherboard/Xeon3000/3210/X7SB4.cfm) [IPMI AOC-IPMI20-E](http://www.supermicro.com/products/accessories/addon/AOC-IPMI20-E.cfm) + +### raid0 disk drive physical order markings on drive carriers + +| | | | | +| ---- | ---- | ---- | ---- | +| 00 | 10 | 20 | 30 | +| 01 | 11 | 21 | 31 | +| 02 | 12 | 22 | 32 | +| 03 | 13 | 23 | 33 | + + +``` +for i in 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16; do + echo -n "1/$i "; + smartctl -i -d hpt,1/$i /dev/hptrr | grep ^Serial; + done +``` +1/1 Serial Number: WD-WMAZA9378538 +1/2 Serial Number: V1KVXSXG +1/3 Serial Number: YGGU1YTA +1/4 Serial Number: WD-WMAZA9520754 +1/5 Serial Number: WD-WCAVY0114154 +1/6 Serial Number: WD-WMC5C0D9L6HV +1/7 Serial Number: WD-WCC6N5UY8H5P +1/8 Serial Number: WD-WCC300759632 +1/9 Serial Number: WD-WCC6N6DDJ7DT +1/10 Serial Number: WD-WCC6N6VTE2NF +1/11 Serial Number: WD-WMC5C0D8Z7FV +1/12 Serial Number: WD-WMC6N0J6S9AV +1/13 Serial Number: WD-WCC4MLULA4S4 +1/14 Serial Number: WD-WMC6N0F8FU0U +1/15 Serial Number: WD-WCAVY0090692 +1/16 Serial Number: WD-WCC6N5CLHYSS + +| Bay | ID | Drive | Name | Serial Number | +| ---- | ---- | ----- | --------- | --------------- | +| 20 | 1/1 | da0 | JBOD-1-1 | WD-WMAZA9378538 | +| 21 | 1/2 | da1 | JBOD-1-2 | V1KVXSXG | +| 22 | 1/3 | da2 | JBOD-1-3 | WD-WCC300755734 | +| 23 | 1/4 | da3 | JBOD-1-4 | WD-WMAZA9520754 | +| 00 | 1/5 | da4 | JBOD-1-5 | WD-WCAVY0114154 | +| 01 | 1/6 | da5 | JBOD-1-6 | WD-WMC5C0D9L6HV | +| 02 | 1/7 | da6 | JBOD-1-7 | WD-WCC6N5UY8H5P | +| 03 | 1/8 | da7 | JBOD-1-8 | WD-WCC300759632 | +| 30 | 1/9 | da8 | JBOD-1-9 | WD-WCC6N6DDJ7DT | +| 31 | 1/10 | da9 | JBOD-1/10 | WD-WCC6N6VTE2NF | +| 32 | 1/11 | da10 | JBOD-1/11 | WD-WMC5C0D8Z7FV | +| 33 | 1/12 | da11 | JBOD-1/12 | WD-WMC6N0J6S9AV | +| 10 | 1/13 | da12 | JBOD-1/13 | WD-WCC4MLULA4S4 | +| 11 | 1/14 | da13 | JBOD-1/14 | WD-WMC6N0F8FU0U | +| 12 | 1/15 | da14 | JBOD-1/15 | WD-WCAVY0090692 | +| 13 | 1/16 | da15 | JBOD-1/16 | WD-WCC6N5CLHYSS | + +* da1 MK0171YFKMA4AG replaced 2022.05.08 +* da12 MK0171YFKMA59G replaced 2022.04.12 +* da8 WD-WCAVY0111166 replaced 2021.11.22 +* da10 WD-WCAVY0127426 replaced 2016.09.15 +* da1 S2F06GX5 replaced 2016.01.2? +* da2 WD-WCAVY0112831 replaced 2014.05.12 +* da5 WD-WCAVY0107135 replaced 2017.03.25 +* da13 W1E0B4NJ replaced 2017.06.xx +* da6 WD-WCAVY0127865 replaced 2018.01.07 +* da6 WD-WMC6N0H8K48M replaced 2021.01.16 +* da9 WD-WCAVY0117958 replaced 2021.03.15 +* da15 WD-WCC4M5VJ4UK3 replaced 2021.06.18 +* da9 WD-WMAY04440674 replaced 2021.08.27 + +## Decommissioned + +dfw0 1ru compute server SuperMicro SYS-6015W-NTRB w/ X7DWU
+dfw1 3ru big raid server SuperMicro CSE-836TQ-R800B w/ X7SBE
+dfw2 2ru Junosphere virtualization server
+ +## DEAD dfw0.psg.com + +dfw0 drives `for i in 4 5 6 7; do echo /dev/ad$i; smartctl -a /dev/ad$i | egrep 'Model|Serial'; done` + +| | | | | +| ---- | ------------------ | ------------ | ---- | +| Bay | Model | Serial | | +| | | | | +| ada0 | ST31000340NS | 9QJ3Q29E | 1TB | +| ada1 | WD20EADS-00R6B0 | WCAVY0388932 | 2TB | +| ada2 | WD2005FBYZ-01YCBB1 | WMC6N0F2KZU6 | 2TB | +| ada3 | ST31000340NS | 9QJ3M5N4 | 1TB | +| | | | | + +dfw0 disk drive physical order + +| ada4 | ada6 | ada5 | ada7 | +| ---- | ---- | ---- | ---- | +| ada0 | ada2 | ada1 | ada3 | + +logical drive labels + +| label/disk00 | ada0s3 | +| ------------ | ------ | +| label/disk01 | ada1s3 | +| label/disk02 | ada2s1 | +| label/disk03 | ada3s1 | + +## DEAD nfs0.dfw.rg.net + +### MoBo +* [PDSME+](http://www.supermicro.com/products/motherboard/Xeon3000/3010/PDSME_.cfm) +* [​AOC-SIM1U+ IPMI Card](http://www.supermicro.com/products/accessories/addon/SIM.cfm) + +### DEAD nfs0.dfw.rg.net Disk Drives +``` +for i in 0 1 2 3 4 5 6 7; do tw_cli /c2/p$i show serial; done +``` + +| Port | Model | Serial | Size | Date | +| -------- | ------------------ | --------------- | ---- | ------------------ | +| p0 | ST4000DM000-1F2168 | Z300L98C | 4TB | don't know | +| p1 | WD4000F9YZ-09N20L1 | WD-WCC5D1DS4012 | 4TB | 2019.04.07 | +| p2 | WD60EFRX-68L0BN1 | WD-WX41DA57H7UJ | 6TB | 2018.03.09 | +| p3 | WD4000F9YZ-09N20L1 | WD-WCC5D2KHHYE8 | 4TB | 2016.06.09 | +| p4 | ST4000DM000-1F2168 | Z300KBMM | 4TB | don't know | +| p5 | ST4000DM000-1F2168 | Z300KBQN | 4TB | don't know | +| p6 | ST4000DM000-1F2168 | Z300L8J5 | 4TB | don't know | +| p7 | WD4000F9YZ-09N20L1 | WD-WMC5D0D7V0L9 | 4TB | 2015.12.13 | +| | | | | | +| p1 | ST4000DM000-1F2168 | Z300FKES | 4TB | removed 2019.04.07 | +| p2 | ST4000DM000-1F2168 | Z300L9T3 | 4TB | removed 2018.03.09 | +| incoming | HUS724040ALS640 | PBK4K70X | 4TB | 2015.12.18 | + +### Physical Drive layout + +| | | | | +| ---- | ---- | ---- | ---- | +| 4 | 5 | 6 | 7 | +| 0 | 1 | 2 | 3 | + +--- +2024.10.19